Alcolock L OEM Handbuch Kalibrierung - Seite 4
Blättern Sie online oder laden Sie pdf Handbuch Kalibrierung für Sicherheitsausrüstung Alcolock L OEM herunter. Alcolock L OEM 8 Seiten. Alcohol interlock, alcohol gas standard
CALIBRATING A HANDSET
Calibration is possible either with a download station or by maintenance code (without a download
station).
Do A or B.
A. WITH A DOWNLOAD STATION
1.
Connect the download station to a power source.
2.
Disconnect the handset from the ECU.
3.
Connect the download station to the handset with a coiled cable and V3/L OEM adapter.
The handset automatically powers on.
4.
Press the left button on the handset to select Cal.
The current handset date and time are displayed.
5.
In the Date/Time screen, press OK to confirm - the SELECT TYPE menu is displayed.
NOTE: If a tachograph is installed, the date and time cannot be changed.
6.
Choose Dry Gas and press OK. The SELECT UNITS menu is displayed.
7.
Select BrAC and press OK. The SELECT DIGITS menu is displayed.
8.
Select 2 digits and press OK. The SELECT VALUE menu is displayed.
Skip the next section and read: "Calibrating a handset (continued)."
B. BY MAINTENANCE CODE (NO DOWNLOAD STATION)
NOTE: The handset must be connected to the ECU.
1.
Power the handset on by holding down any navigation button.
2.
Access the menu screen by pressing and holding the left button.
NOTE: Where available, press and hold the right navigation button to exit a current
screen / menu.
3.
Press Next to scroll to System Maintenance, and press Select.
4.
Input the daily System Maintenance Code (obtained from ITE). To do so:
• Press [+] / [-] repeatedly to increment / decrement a digit.
• Press Next to move the cursor to the next digit.
5.
With the code entered, press Next to move the cursor to OK, and press Select.
6.
In the service menu, press Next to go to Calibrate, and press Select.
7.
In the Date / Time screen, do I or II:
I.
If the date and time are correct, press OK – the SELECT TYPE menu is displayed.
II.
If the date or time is incorrect, change as follows:
NOTE: If a tachograph is installed, the date and time cannot be changed.
a. Press Set to enter the Set Clock screen.
b. Press [+] / [-] repeatedly to increment / decrement a digit.
c. Press Select to move the cursor to the next field.
2
ALCOLOCK L OEM