Alcolock V3 Handbuch Kalibrierung - Seite 6

Blättern Sie online oder laden Sie pdf Handbuch Kalibrierung für Sicherheitsausrüstung Alcolock V3 herunter. Alcolock V3 8 Seiten. Alcohol gas standard

Alcolock V3 Handbuch Kalibrierung
7.
Continue holding the valve down until the handset tone stops, even after the handset clicks.
An Analyzing message is displayed followed by a Wait message and 0:45 second
countdown. The handset is ready for the second sample when the Turn on Gas message is
displayed.
Depending on the sensor calibration drift, up to 4 samples may be required.
If only 2 tests are required, a Verification OK message is displayed when the calibration is
complete.
If 3 or 4 tests are required, a Calibration OK message is displayed when calibration is
complete.
8.
Do I or II:
I.
For calibration with download station, disconnect the handset from the download
station and connect back to the ECU.
II.
For calibration without download station, press the right button to finish (there is also
the option to retry by pressing the left button).
The V3 handset returns to ready state and Blow for 5 seconds is displayed.
NOTE: If the calibration fails on numerous attempts, the sensor may need
replacement. Contact an authorized service provider for return instructions.
4
CALIBRATION IS COMPLETE
ALCOLOCK V3 SERIES B-2