Xerox Versant 2100 Press Kundenerwartung & Installationshandbuch - Seite 40

Blättern Sie online oder laden Sie pdf Kundenerwartung & Installationshandbuch für Drucker Xerox Versant 2100 Press herunter. Xerox Versant 2100 Press 49 Seiten. Entry production color presses
Auch für Xerox Versant 2100 Press: Sicherheitshandbuch (45 seiten)

Xerox Versant 2100 Press Kundenerwartung & Installationshandbuch
Installation
Optional feeding / finishing device
Advance High Capacity Feeder
Interface Module + GBC
AdvancedPunch Pro
Interface Module + High Capacity
Stacker (HCS)
Interface Module + Standard Finisher
(without C/Z Folder)
Interface Module + Standard Finisher +
C/Z Folder
Interface Module + Booklet Maker
Finisher (without C/Z Folder)
Interface Module + Booklet Maker
Finisher + C/Z Folder
SquareFold Trimmer Module
Standard Finisher Plus* without C/Z
Folder
*Includes Finisher Module and
Finishing Transport
Standard Finisher Plus* with C/Z Folder
*Includes Finisher Module and
Finishing Transport
2-Knife Trimmer

Electrical Requirements

All press optional accessories and print servers should be placed within 6
feet (3 meters) of wall outlets. Ensure that there are enough wall outlets
available for optional accessories and the print server.
Press (Left and Right modules) Electrical Requirements
Electrical requirements must be satisfied prior to equipment delivery. The
Press requires a dedicated 30 Amp service.
Item
Main processor
Nominal Voltage
 North America (NA): 208-240 VAC (XC) -
10%/+6%
 Europe: 220-240 VAC (XE) ±10%
Amperage circuit
30*
*Requires a 30A circuit and receptacle
Current rating
24
Cycles
50/60 Hz Single Phase
Frequency (Hz)
 NA: 50/60 ±3%
 Europe: 50 ±3%
Power
 NA: 208V, 4.992KW or less
consumption
 NA: 240V, 5.76KW or less
 Europe: 220V, 5.28KW or less
 Europe: 240V, 5.76KW or less
Power Cord Length
10 feet/3 meters
Customer Expectation and Installation Guide
Required number of kits
2 Kits
1 Kit
 
3 Kits
2 Kits
3 Kits
2 Kits
3 Kits
1 Kit
3 Kits
4 Kits
2 Kits
Xerox Confidential
Item
Main processor
Plug/Receptacle
 North America Plug: NEMA 14-30P
Diagram
 North America Receptacle: NEMA 14-30R
 
 
 
 
 
 
 
A single power cord (USA plug and receptacle
diagram shown above) is required for the
print engine.
 
 Europe: PCE Shark 023-6 Plug
 Europe: receptacle that mates to the PCE Shark
023-6 plug
Advanced HCF Electrical Requirements
International Requirements
Each Advanced HCF (standard and optional) requires an additional 100-240
VAC or 208-240 VAC country-specific power receptacles.
USA Requirements
In the USA, each Advanced HCF (standard and optional) requires one
additional NEMA 5-15R or 5-20R receptacle; refer to the following table
Item
Advanced HCF
Current/run power
3 amps/65 watts
Voltage (VAC)
100-240
Power cord
8.2 feet/2.5 meters
length
Receptacle NEMA
5-15R or 5-20R
part number
Electrical Requirements for Optional Devices
International Requirements
Each optional finishing device requires an additional 100-240 VAC or
208-240 VAC country-specific power receptacles.
NOTE
Use surge protection only as required, and it is the responsibility of
the customer.
USA Requirements
Each optional finishing device requires one additional NEMA 5-15R or
5-20R receptacle; refer to the following diagram and table.
NOTE
Use surge protection only as required, and it is the responsibility of
the customer.
Xerox
Versant™ 2100 Press
®
35