How are problems identified and reported?
Capture & Transfer
20
To capture and transfer data to Xerox in a single step
1. Select [Problem Reporting: Capture & Transfer]. Once the
Capture & Transfer window opens, you are informed that the
DFE must not be ripping or printing while a Data Capture is in
progress.
NOTE: Required information fields are designated with an asterisk
2. Select a Data Type option:
•
Machine
•
Job
•
Machine & Job
If you select Machine or Machine & Job, the following Machine
capture options are available by expanding the Advanced
Machine Data Types menu:
•
Capture DFE Data Only
•
Capture IOT Data Only
•
Capture DFE & IOT Data
NOTE: The Advanced Machine Data Type menu is grayed out
if Job is the Data Type option selected.
3. If the Data Type option you select is Job or Machine & Job,
you can select a Job Type and a Job ID from the drop-lists.
These menus are unavailable if you select Machine as the
Data Type.
4. Enter a Call Log ID number. This field is blank by default.
NOTE: The Call Log ID facilitates transmission tracking. This
information is provided by Xerox Support.
5. Enter a Fault Code. The Fault Code is the status or error
message number provided by the DocuSP interface. This field
is optional and is blank by default.
6. Type in a description of the current issue that requires data
capture. The information you enter allows Xerox to better
understand the issue. This field is required and the capture
process will not proceed until a problem description is entered.
7. Click the [Start Capture & Transfer] button.
The dialog refreshes and shows the status of the capture
process. The status bar indicates the following states:
•
Preparing Data
•
Capturing DFE Data (if applicable)
User Guide