Alderon Industries VersAlarm I/O VLIO-0002 Schnellstart-Handbuch - Seite 2
Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Sicherheitssystem Alderon Industries VersAlarm I/O VLIO-0002 herunter. Alderon Industries VersAlarm I/O VLIO-0002 2 Seiten. Indoor/outdoor alarm panel
Step 5: Install Bottom Cover
Line up the bottom enclosure cover with the grooves (5A), then slide
directly upward (5B) until it meets the top of the enclosure so the screw
hole is lined up and replace the screw at the bottom of enclosure.
5A
5B
Step 6: Power Alarm and Quick Test
After all wiring and installation steps have been completed, power the
alarm by plugging the pre-installed power cable into a standard 120VAC
wall outlet or power receptacle. Make sure the outlet is on a separate
circuit breaker from any other device and not on a switched receptacle
to maintain power integrity. Use the features list and diagram below to
perform a quick test of the alarm to make sure it is working properly.
Note: For complete wiring, installation instructions, or troubleshooting,
refer to the user guide for this model by scanning QR code.
1
4
3
8
5
Included with Product
▪ (1) VersAlarm™ I/O alarm panel
▪ (2) Pre-installed cable grips
▪ (1) Pre-installed, male, 120VAC, 6-foot power cable
▪ (1) Pre-installed alarm float switch
▪ (1) RubberLox™ pipe clamp
▪ (1) Wago connector
Customer Support
Online
alderonind.com
Email
QR Code
Scan code for full product details
Specifications
VersAlarm™ I/O
Primary Power:
Power:
Certifications:
Auxiliary Contacts:
Enclosure:
FCC Part 15: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: increase the separation between the equipment and receiver, connect the equipment into an
outlet on a circuit different from that to which the receiver is connected, consult the dealer or an experienced radio/TV technician for help. Caution:
changes / modifications not approved by Alderon Industries could void the user's authority to operate the equipment.
Altra™ Alarm Float Switch
Electrical:
Operating Temperature: 0 - 140° F
Cable Type:
Float Housing:
Switching Differential:
Switching Configuration: Single Pole, Single Throw (Normally Open or Normally Closed)
Certifications:
VersAlarm
I/O - Features
™
1
2
2
3
4
5
6
7
8
9
10
7
11
6
12
9
120VAC, 50/60Hz
2.64 Watts maximum (alarm condition)
FCC Part 15 (US/Canada), CSA (US/Canada)
24VDC @ 0.5 Amps maximum
Outdoor, rated Type 3R
5 Amp, 120/240VAC
SJOOW (UL/CSA), flexible, 18 gauge, 2-conductor, water/oil resistant
Polypropylene
20° total (narrow angle) and 90° total (wide angle)
CSA (US and Canada)
Power On Indicator - Green LED illuminates enclosure cover
Alarm Beacon - Red LEDs illuminate enclosure cover
Alarm Buzzer - Annunciates to indicate an alarm condition
Test/Silence Pushbutton - Activates alarm, silences alarm buzzer
Sensor Input - Terminals for the alarm float switch connection
Auxiliary Contacts - Interface with external device, 24VDC @ 0.5A maximum
Power Mains Input - Terminals for line (L1) and neutral (N), 120VAC
Power Indicator Turn Off - Flip switch down to turn off green power LED
QR Code - Scan code for additional product information (alderonind.com)
Cable Grips (not shown) - Pre-installed for easy installation
6-Foot Power Cable (not shown) - Pre-installed, male, 120VAC
Alarm Float Switch/Sensor (not shown) - Pre-installed for easy installation