For options 20 - 23, use the installer test o
determine the max
imum allowable airflow.
20 Maximum Upstairs Airflow in Heating
Factory Default: 150%. Range: 100% to 155%.
Touch the
UP/DOWN
keys to
select the maximum allowable
upstairs airflow in heating.
Touch
NEXT
or
ENTER
.
21 Maximum Upstairs Airflow in Cooling
Factory Default: 140%. Range: 100% to 155%.
Touch the
UP/DOWN
keys to
select the maximum allowable
upstairs airflow in cooling.
Touch
NEXT
or
ENTER
.
22 Maximum Downstairs Airflow in Heating
Factory Default: 150%. Range: 100% to 155%.
Touch the
UP/DOWN
keys to
select the maximum allowable
downstairs airflow in heating.
Touch
NEXT
or
ENTER.
23 Maximum Downstairs Airflow in Cooling
Factory Default: 140%. Range: 100% to 145%.
Touch the
UP/DOWN
keys to
select the maximum allowable
downstairs airflow in cooling.
Touch
NEXT
or
ENTER
.
n pages 7-8 to
Upstairs
Option
Heat
Airflow %
Downstairs
NEXT
ENTER
Upstairs
Option
Airflow %
Cool
Downstairs
NEXT
ENTER
Upstairs
Option
Heat
Airflow %
Downstairs
NEXT
ENTER
Upstairs
Option
Airflow %
Cool
Downstairs
NEXT
ENTER
24 Maximum Temperature Differential
o
Factory Default: 2 F.
Range: 0 to 10 F
Maximum allowable temperature difference between the upstairs and
downstairs temperatures. When the temperature difference is equal to
or greater than the allowed differential, the airflow is adjusted.
Touch the
UP/DOWN
keys to
select the maximum allowable
temperature difference between
the upstairs and downstairs.
Touch
NEXT
or
ENTER.
25 Wireless Home Number
Factory Default: 1.
When 2 or more Comfort365 sytems with wireless sensors are installed
within 300 feet of one another, the installations have to be set to
different Home Numbers used in wireless communication
Touch the
UP/DOWN
keys to
select a new Home Number for
one of the installations.
Touch
NEXT
or
ENTER.
26 Thermostat Location
Factory Default: dS
Range: dS or uS
In most homes the thermostat is located downstairs. If the thermostat
is located Upstairs this option can be used to instruct the thermostat to
where it is installed.
Touch the
UP
key to select the
thermostat located Upstairs
(uS) or press the Down key to
selct Downstairs (dS).
Touch
NEXT
or
ENTER.
27 Factory Restore
Touch
NEXT
or
ENTER
to
return to normal thermostat
operation. Touch the hidden
BACK
key to return to previous
option.
To restore factory settings,
touch
ENTER
, then touch the
UP
key.
7
o
o
Option
NEXT
Range: 1 to 8
Home
NEXT
Option
NEXT
WARNING! Factory Restore
resets ALL settings.
Option
NEXT
ENTER
ENTER
ENTER
ENTER