eControls RT2 Handbuch für Benutzer und Installateure - Seite 3
Blättern Sie online oder laden Sie pdf Handbuch für Benutzer und Installateure für Kontrolleinheit eControls RT2 herunter. eControls RT2 8 Seiten. Wireless whf control
Auch für eControls RT2: Handbuch für Hausbesitzer und Installateure (12 seiten)
TEMPERATURE CONTROL
OPERATION
1
Set the Cooling Temperature
2
Turn Econo Cooling On or Off
3
Change Outdoor Temperature Limit
When EconoCool is On, the RT2 activates the WHF
when the indoor temperature is 1 degree warmer than
the WHF cooling temperature. The WHF is turned Off by
the RT2 when the cooler outdoor air has lowered the
indoor temperature 1 degree below the WHF cooling
temperature. The WHF will cycle On and Off as needed
to keep the space comfortable.
When an optional outdoor temperature sensor is
installed, the WHF will not be activated if the outdoor
temperature is above the outdoor temperature limit.
This improves energy efficiency and comfort by inhibiting
WHF operation when the outdoor temperature is too
warm to provide cooling.
Setting the Cooling Temperature
1
Just like your air conditioning thermostat, set the cooling
temperature desired using the Up and Down keys.
Outdoors
Press the UP or DOWN key to set the
Indoors
o
F
cooling temperature.
Cool
Link
ed
Set To
Econo
Cooling
ON
Menu
Turn Econo Cooling On or Off
2
When Econo Cooling is turned On, the WHF will operate
if the indoor temperature is warmer than the WHF
cooling temperature. If an optional outdoor temperature
sensor is installed, the outdoor temperature needs to be
cooler than the outdoor temperature limit.
Outdoors
Press in this area to turn Econo
Indoors
o
F
Cooling On or Off.
Cool
Link
ed
Set To
Econo
Cooling
ON
Menu
HOMEOWNER SECTION
3
If an outdoor temperature sensor is installed, the outdoor
temperature is displayed.
Outdoors
TIMER CONTROL OPERATION
1
2
3
In Timer mode a 1 to 8-hour timer is started when
EconoCool is turned On. The WHF is activated and at
the end of the timer interval, the WHF is turned Off.
1
The WHF is turned On and will operate for the preset
time period when EconoCool is turned On.
3
Change Outdoor Temperature Limit
Press here to set the
Outdoor temperature Limit.
Indoors
o
F
Press the UP or DOWN key to
change the Outdoor Temperature
Limit and then press the ENTER
key to return to normal operation.
Enter
Start a Timer Sequence
End a Timer Sequence
Change the Preset Timer Interval
Start a Timer Sequence
Indoors
o
F
Link
ed
Econo
Cooling
Menu
OFF
Press here to turn the
WHF On for the preset
Timer interval.
Outdoors
Indoors
o
F
Cool
Link
ed
Set To
Econo
Cooling
ON
Menu
Indoors
o
F
Link
ed
Econo
Cooling
Menu
On
Displays the time
remaining in the
timer cycle.