Calian SatService sat-nms Benutzerhandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Controller Calian SatService sat-nms herunter. Calian SatService sat-nms 17 Seiten. Power sensor
averaging
Shows the averaging mode actually used by the power sensor.
input
Shows the input amplifier range actually used.
sensivity
alarm
Shows the alarm threshold actually set at the
threshold
falls below this limit, an alarm is reported and the normally closed alarm contact is
opened.
alarm state
Shows the actual alarm state (OK /FAULT)
3.3 Operational Parameters
The page 'Setup' contains the power sensor's operational parameters. The page displays a table with the
parameters actually set as a browser entry form. To change a parameter, enter the new value or select the
desired option from the drop down list and then click to the 'SUBMIT' button at the bottom of the page.
Parameters remain unchanged unless you click to this button.
The table below lists the settings provided by this page.
Parameter
Description
Name
input
Sets the sensivity range, the power sensor uses.
sensivity
AUTO makes the power sensor select the appropriate range automatically.
LOW selects the low sensivity range (for high levels).
HIGH selects the high sensivity range.
It is strongly recommended to operate the power sensor with AUTO setting.
averaging
Sets the filter, the power sensor applies to the measured values. Valid choices are
OFF
FAST
SLOW the sensor displays the average of 48 readings.
Averaging is done on the base on the 8 or 48 samples the power sensor recently read.
frequency
Here you may enter the frequency of the measured signal in MHz. If this parameter is not
compensation
zero, the power sensor looks up the frequency response calibration offset for the given
frequency and adds this offset to each measured value before it is displayed. The power
sensor accepts integer numbers on the range 0 .. 19000.
additional
The value [dB] specified with this parameter is added to the measured power before it is
level offset
displayed and compared to the fault threshold value. If value is set to zero, the power
sensor shows the power which is measured at it's input connector. The valid range for
'offs' is -99.99 to 99.99.
alarm
Defines the alarm threshold value. If the displayed power value (with any user defines
threshold
offset and frequency response calibration already applied) drops below this limit, the
power sensor reports a 'low signal' alarm and opens the fault relay contact. To disable the
threshold, set it to -99.99.
note
You may enter a note / comment here which replaces the 'Power Reading' label on the
power sensor's entry page. The label may be set to describe what the power sensor
actually is measuring.
(C) 2020, SatService GmbH
no averaging.
the sensor displays the average of 8 readings.
www.satnms.com
Setup
page. If the displayed power reading
PS-UM-2002 Page 9/16