Yamaha DG-Stomp Service-Handbuch - Seite 31

Blättern Sie online oder laden Sie pdf Service-Handbuch für Verstärken Yamaha DG-Stomp herunter. Yamaha DG-Stomp 43 Seiten. Guitar pre-amplifier with effects
Auch für Yamaha DG-Stomp: Ergänzendes Handbuch (1 seiten), Benutzerhandbuch (32 seiten)

Yamaha DG-Stomp Service-Handbuch

ERROR MESSAGES

If an error occurs during operation, one of the following error message numbers will appear on the display.
E1
: MIDI Receive Buffer Full
CAUSE:
Too much MIDI data is being received by the DG amplifier at one time.
SOLUTION: Try reducing the amount of data being sent or, break the data into smaller blocks.
E2
: Communication Error.
CAUSE:
An abnormality is detected during MIDI communications.
SOLUTION: Check all connections, etc. and try again.
E3
: Bulk Receive Check Sum Error.
CAUSE:
The check sum does not match the received MIDI bulk data.
SOLUTION: Check all connections and data, and try again.
E4
: Bulk Receive Data Abnormality.
CAUSE:
An abnormality is detected in the received MIDI bulk data.
SOLUTION: Check all connections and data, and try again.
E5
: Backup Battery Error.
CAUSE:
Backup battery power is depleted.
SOLUTION: Continued use of the device will result in the loss of data. Return the device to the music
dealer where you purchased it or, have the battery replaced.
DG-Stomp
31