Alert Numbers and Content
If a problem occurs in the XMV, the [ALERT] indicator will flash and an alert number will appear in the display.
The alert numbers, the corresponding content, and the appropriate actions are listed below.
Alert number
No display
(only [ALERT] is lit)
The device has not started up correctly.
001.–008.
The internal backup battery has been completely
010.
exhausted or is not installed.
The internal backup battery has run extremely low, and
011.
it is possible that the internal memory has been cleared.
The internal backup battery has only a small amount of
012.
power remaining.
A problem has occurred with the internal clock, and it
013.
has been initialized (January 1, 2000, 0:00)
015.
The settings saved in internal memory have been lost.
016.
A memory problem has occurred.
021.
The word clock master has become unlocked.
The digital signal being input to the [YDIF IN] connector
022.
is not synchronized to the word clock of this device.
The digital signal being input to the [YDIF IN] connector
023.
is not continuously synchronized to the word clock of
this device.
There is a problem with the connection of the [YDIF IN]
030.
connector.
040.
Duplicate IP addresses.
041.
IP address was not set within 60 seconds of startup.
043.
Too many devices are connected to the network.
050.
The UNIT ID is set to "00."
Devices with identical UNIT IDs were found connected
051.
within the same network.
The power supply was shut down because d.c. was
100.
detected on a speaker output.
The power supply was shut down because its tempera-
101.
ture exceeded the allowed limit.
Meaning
XMV4280/XMV4140/XMV4280-D/XMV4140-D Owner's Manual
Response
Turn the power off, then turn on after waiting at least 5
seconds. If this does not solve the problem, please ini-
tialize the memory. Should this also fails, contact your
Yamaha dealer.
When you turn off the power, the current settings will be
lost, and will return to the default values. Please stop use
immediately, and contact your Yamaha dealer.
This does not affect the operation of the device. How-
ever, if you continue using the device, the settings may
be lost and reset to the default values. Contact your
Yamaha dealer as soon as possible.
If this occurs each time you turn on the power, it is possi-
ble that the internal backup battery has run down or that
the device has malfunctioned. Contact your Yamaha
dealer.
If this occurs only once, an abnormality was detected
with the clock setting and it was initialized; use MTX Edi-
tor to set the time.
Either the internal backup battery has run low, or the
device has malfunctioned. Contact your Yamaha dealer.
Contact your Yamaha dealer.
Make sure that the word clock signal is being input cor-
rectly.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
Change the IP addresses so that there are no dupli-
cates.
Please check rear panel DIP switch 6 (IP Setting). If DIP
switch 6 is set to "PC," use MTX Editor or DHCP server
to specify the device IP address.
Reduce the number of devices connected to the net-
work.
Set the UNIT ID to something other than "00."
Change the UNIT ID so that there are no duplicates.
It is likely that the device has malfunctioned; immediately
stop using the device and contact your Yamaha dealer.
Turn the power off, let the power supply cool down, then
turn the power on again.
Continuous high-power output will cause high tempera-
tures, so please lower the output level. If the temperature
is still high, check whether dirt or a foreign object could
have clogged the cooling fan, and clean the fan if neces-
sary.
Appendix
27