Ecoplus ZR9W Series Gebrauchsanweisung - Seite 11

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Warmwasserbereiter Ecoplus ZR9W Series herunter. Ecoplus ZR9W Series 20 Seiten. Domestic hot water unit, air source heat pump with external coil

3.CONTROLLER INTRODUCTION
2.1.2)Unit Status
Press "
" or "
cursor to " Unit Status" , then
press "
" to confirm and enter
to interface of FIG.6.
This interface display the current
real /actual running status , para-
meter data are not adjustable .
2.2)
Parameter
Choose "Parameter "from Function
Screen to access "Parameter "Screen,
then press "ENTER" button to access
the "Parameter "
2.2.1)Operation
Press "
" or "
to "Operation" then press "
confirm and enter interface of FIG.8.
Press "
" or "
parameter value , then press "ESC" to
confirm . Press " ESC" again to return
to last interface .
"Out water temp"adjustable range:10-60℃
"ΔT1 (heating)"adjustable range:2-15℃
2.2.2)Aux Heating
Press "
" or "
cursor to "Aux Heating" ,then press
"
" to confirm and enter interface
of FIG.9.
Press "
" or "
parameter value , then press " ESC"
to confirm changes , press "ESC" to
return to last interface.
"Start temp. adjustable range:30~90℃
"
"Start delay "adjustable range:0~90min
" to move the
see Fig.7.
" to move the cursor
" to
" to change the
" to move the
" to choose
Tank top temp.
Tank bottom temp.
Pipe temp.
Evap. temp.
Ambient temp.
Swell valve
1.0 Operation
2.0 Aux heating
3.0 Defrost
4.0 Save
5.0 Disinfection
6.0 Swell valve
1.1 Out water
1.2 ▲T1 (heating)
2.1 Start temp.
2.2 Start delay
9
31℃
32℃
-3℃
32℃
25℃
350N
Fig.6
Fig.7
55℃
5℃
Fig.8
45℃
30min
Fig.9