Clark-Reliance Jerguson LumaStar EPL-100 Handbuch für Installation, Betrieb und Wartung - Seite 2
Blättern Sie online oder laden Sie pdf Handbuch für Installation, Betrieb und Wartung für Arbeitslicht Clark-Reliance Jerguson LumaStar EPL-100 herunter. Clark-Reliance Jerguson LumaStar EPL-100 12 Seiten.
Auch für Clark-Reliance Jerguson LumaStar EPL-100: Handbuch für Installation, Betrieb und Wartung (12 seiten)
1
STORAGE and HANDLING
®
The Jerguson
LumaStar™ Intrinsically Safe LED Illuminator meets or exceeds all applicable
specifications when shipped from the factory.
All units should be inspected upon receipt to ensure that no damage has been incurred during transit. If there has
been damage, a claim should be filed with the carrier immediately. Unit should be stored in an area protected
from the elements and corrosive fumes, in a secure manner where they can neither fall, nor be struck by other
objects. Care should be taken to protect the window and the end connections from damage. Avoid placing any
objects directly on the light at any time.
COMPONENTS
There are 4 main components required for the LED illuminator system: the light bar, a 24VDC power
supply, zener diode barrier, and cable with optional field-wireable connector. The cable may have more than one
piece depending on the customer requirements. Questions regarding acceptable applications should be directed to
®
The Clark-Reliance
Corporation.
ELECTRICAL CONNECTION
CAUTION: All lights are tagged with the service conditions for that particular unit. These specifications
®
are located on the Jerguson
tag on the enclosure housing, and are contained in the "Specifications" section
of this manual. Review the ratings prior to installation and again prior to start-up.
NOTE: All installation steps should be performed by a qualified technician and should be executed in
accordance with all applicable national and local codes.
The light and field-wireable connector / enclosure should be checked to ensure that they contain no foreign
matter, and that the end connections are clean and undamaged.
NOTE: If desired, the light may be installed onto the glass gauge prior to connecting electrical.
CAUTION: Before wiring LED illuminator verify that the power circuit is off. The power supply and
zener diode barrier should be located in a non-hazardous area. The power supplied to the LED illuminator
is intrinsically safe. See figure 1.
Figure 1: Typical Layout
16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
www.clark-reliance.com ● [email protected]