Clarke 7614052 Handbuch für Betrieb und Wartung - Seite 10
Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Elektrowerkzeug Clarke 7614052 herunter. Clarke 7614052 17 Seiten. 20 tonne hydraulic press
TROUBLESHOOTING
Problem
Pump unit will not work Dirt on valve seat/worn
Pump will not produce
pressure
Pump feels hesitant
under load
Pump will not deliver
pressure
Pump feels hesitant
under load
Pump will not lower
completely
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Probable Cause
seals
Air-lock
Reservoir could be over-
filled or have low oil level.
Pump cup seal could be
worn out.
Air-lock
10
Remedy
Bleed pump or have unit
overhauled with new seals
Open the release valve
and remove the oil filler
plug. Pump the handle a
couple of full strokes and
close the release valve.
Replace the filler plug.
Check oil level by removing
the filler plug & topping up
if required.
Have the cup seal
replaced.
Release air by removing
the filler plug.