applicable pressure adjuster on the gas supply
pipe.

ADJUSTMENT OF MINIMUM LEVEL

To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob and the gasket.
WARNING! Pay attention not to
damage the gasket. Do not use sharp
tool to remove it.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
from natural gas G20 20 mbar to liquid gas,
fully tighten the bypass screw in.
from liquid gas to natural gas G20 20 mbar,
undo the bypass screw approximately 1/4
of a turn (1/2 of a turn for Multi Crown
burner).
6. Reassemble the gasket and the knob.
WARNING! Make sure to place the
gasket exactly in the original position.
WARNING! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
This appliance is supplied with a mains cable. It
has to be supplied with a correct plug which
can hold the load that the rating plate rates.
Make sure that you install the plug in a correct
socket.
Always use a correctly installed shockproof
socket.
Make sure that there is an access to the mains
plug after the installation.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a
letter "N" on it. Connect the brown (or
black) phase cable to the terminal
which has a letter "L". Keep the phase
cable connected at all times.