Zanussi ZGG65414XA Benutzerhandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kochfeld Zanussi ZGG65414XA herunter. Zanussi ZGG65414XA 16 Seiten. Hob
Auch für Zanussi ZGG65414XA: Benutzerhandbuch (16 seiten), Benutzerhandbuch (32 seiten)

Zanussi ZGG65414XA Benutzerhandbuch
Important! Make sure that the gas supply
pressure of the appliance obeys the
recommended values.
If the supplied pressure has not the specified
value, it is necessary to assemble a proper
pressure regulator in compliance with the
standard UNI EN 88. For Liquid Gas (LPG) the
use of pressure regulator is allowed only if they
are in compliance with UNI EN 12864. The ad-
justable connection is fixed to the comprehen-
sive ramp by means of a threaded nut G 1/2".
Screw the parts without force, adjust the con-
nection in the necessary direction and tighten
everything.
A
A) End of shaft with nut
B) Washer
C) Elbow (if needed)
Rigid connection:
Carry out connection by using metal rigid pipes
(copper with mechanical end) (UNI-CIG 7129).
Flexible connection:
Use a flexible pipe in stainless steel (UNI-CIG
9891) with a maximum length 2 m.
Important! When installation is complete,
make sure that the seal of each pipe fitting is
correct. Use a soapy solution, not a flame!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burn-
er.
3. With a socket spanner 7 remove the injec-
tors and replace them with the ones which
are necessary for the type of gas you use
(see table in "Technical Information" chap-
ter).
10
B C
4. Assemble the parts, follow the same pro-
cedure backwards.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply. You can find this plate in the
package supplied with the appliance.
If the supply gas pressure is changeable or dif-
ferent from the necessary pressure, you must fit
an applicable pressure adjuster on the gas sup-
ply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-pass
screw position.
A) The by-pass screw
• If you change from natural gas G20 20 mbar
to liquid gas, fully tighten the adjustment
screw in.
• If you change from liquid gas to natural gas
G20 20 mbar, undo the by-pass screw ap-
proximately 1/4 of a turn.
Warning! Make sure the flame does not
go out when you quickly turn the knob
from the maximum position to the minimum
position.
Electrical connection
• Make sure that the rated voltage and type of
power on the rating plate agree with the volt-
age and the power of the local power supply.
• This appliance is supplied with a mains ca-
ble. It has to be supplied with a correct plug
which can hold the load that the rating plate
A
www.zanussi.com