Zanussi ZKF 641 X Installations- und Betriebsanleitung - Seite 15
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Kochfeld Zanussi ZKF 641 X herunter. Zanussi ZKF 641 X 20 Seiten. Ceramic glass hob

Installation Instructions
1
Important! The new appliance may only be in-
stalled and connected by qualified person-
nel.
Please observe this instruction, otherwise the
warranty will not cover any damage that may
occur.
Technical Data
Appliance dimensions
Width
Depth
Height
Worktop cut-out dimensions
Width
Depth
Corner radius
Cooking rings
Position
Diameter
Front left
180mm
Rear left
180mm
Rear right
145mm
Front right
145mm
Connection voltage
Maximum connected load power
Regulations, Standards,
Directives
This appliance meets the following standards:
• EN 60 335-1 and EN 60 335-2-6
relating to the safety of electrical appliances for
household use and similar purposes and
• EN 60350, or DIN 44546 / 44547 / 44548
relating to the operating features of electric coo-
kers, hobs, ovens, and grills for household use.
• EN 55014-2
• EN 55014
• EN 61000-3-2
• EN 61000-3-3
• relating to basic requirements for electro-magnetic
compatibility protection (EMC).
5
• 73/23/EWG dated 19.02.1973 (Low Voltage Direc-
tive)
• 89/336/EWG dated 03.05.1989 (EMC Directive in-
cluding Amending Directive 92/31/EWG).
1
572 mm
502 mm
• A device must be provided in the electrical installa-
47 mm
tion which allows the appliance to be disconnected
from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting
cut-outs, fuses (screw type fuses are to be re-
moved from the holder), earth leakage trips and
560 mm
contactors.
490 mm
• In respect of fire protection, this appliance corre-
R5
sponds to EN 60 335-2-6. This type of appliance
may be installed with a high cupboard or wall on
one side.
• Drawers may not be fitted underneath the hob.
Power
• The installation must guarantee shock protection.
1700W
• The kitchen unit in which the appliance is fitted
1700W
must
1200W
DIN 68930.
1200W
• For protection against moisture, all cut surfaces
are to be sealed with a suitable sealant.
230 V ~ 50Hz
• On tiled work surfaces, the joints in the area where
the hob sits must be completely filled with grout.
5,8kW
• Ensure that the seal is correctly seated against the
work surface without any gaps. Additional silicon
sealant must not be applied; this would make re-
moval more difficult when servicing.
• The hob must be pressed out from below when re-
moved.
For Australia:
• CAUTION: The surface temperature exceeds 95°C.
To avoid a hazard, underbench access must be re-
stricted.
• The cable used to connect the appliance to the
mains electricity
temperature rating of V90HT for the complete dis-
tance of cable run under the hob.
This appliance complies with the following EU
Directives:
Safety Instructions for
the Installer
satisfy
the
stability
supply must have a minimum
requirements
of
15