Clarke PEV11C50 Betriebs- und Wartungsanleitung - Seite 9

Blättern Sie online oder laden Sie pdf Betriebs- und Wartungsanleitung für Luftkompressor Clarke PEV11C50 herunter. Clarke PEV11C50 16 Seiten. Air compressor electric motor driven
Auch für Clarke PEV11C50: Handbuch für Betrieb und Wartung (17 seiten)

Clarke PEV11C50 Betriebs- und Wartungsanleitung
TROUBLE SHOOTING CHART
1. Any remedial work that may be required must be carried out by a qualified
electrician/engineer.
2. Disconnect from the mains supply before removing any parts from the
compressor.
3. Empty Air Receiver of Air before dismantling any part of the compressor unit's
pressure system.
4. If your compressor develops a fault do not use until the fault has been rectified.
SYMPTOM
Compressor will not Fault in electrical
start automatically.
Fuses keep blowing. Inadequate size fuse
Compressor unit
starts, but stops
again after only a
few revolutons.
IMPORTANT!
PROBABLE CAUSES
installation.
a) current supply failure.
b) voltage drop.
c) motor starter faulty.
d) motor incorrectly
connected or faulty.
e) starter overload has
tripped out.
f) Pressure switch
defective.
g) Fuse blown.
installed.
Fault in motor.
Non-return valve leaking
(compressor unit is on load
during start).
Non-return valve blocked,
possibly frozen up.
Solenoid valve leaking or
defective (only applies to
10 hp machines and above).
Let an electrician check
electrical installation.
Reset by depressing
button.
Have pressure switch
changed by an electrician.
Check fuse rating - replace.
Replace with reference to
chart on page 4.
Contact Clarke Service
Disconnect from the mains
supply and empty air
receiver. Clean or replace
non-return valve.
Thaw non-return valve out
(Unit must be installed in
frost-free place).
Contact Clarke Service
Department
9
REMEDY