H1/3 WHITE/BLUE Channel 3 (-) 200 mA output
The function of this wire will be selected when programming the features. This output will deliver a 200 mA (-)
and will be activated when pressing simulteneously buttons
and
on the 473T transmitter or
when using the 470T mini transmitter you must press on the
et
simultaneously.
H1/5 GREEN (-) Program activation input/Zone 3
This input is used for programming of the main control unit or can also be used as a (-) zone 3 trigger input.
Will need to be grounded for programming.
H1/6 BLUE (-) Zone 4, instant trigger input
This wire will respond to a negative input with an instant trigger. This input will be used with the 507M Tilt
detector and will report on Zone 4.
H1/8 BLACK (-) Chassis ground input
This wire should be connected to the (-) terminal of the Battery . Some recreational vehicles chassis may represent
a poor ground reference that can result in erratic performance from the security system control module. We recom-
mend grounding all your components, including the siren, to the same point.
H1/9 YELLOW Zone 5, (+) Ignition input
This wire must be connected to the same circuit as the starter kill relay. It should show 12 volts when vehicle
key is at the "ON" position also while cranking and will show 0 volts when in the "OFF" position. If no 12 volts
shows while cranking, please select another ignition source.
H1/10 BROWN (+) Siren output
Connect the brown wire of the security system to the (+) activation wire of the backup siren.