Aleko AC1400 Benutzerhandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Toröffner Aleko AC1400 herunter. Aleko AC1400 16 Seiten. Sliding gate operator

Aleko AC1400 Benutzerhandbuch
AC1400 SLIDING GATE OPERATOR
is complete, return DIP switch 1 to OFF position immediately. Thus the width of
pedestrian mode has been canceled, the auto-close function of pedestrian mode has
been reserved.
Note: the new auto-close time of pedestrian mode has been re-programmed in the device
and replaced the original auto-close time of pedestrian mode that you have been set in
Set auto-close function of pedestrian mode section.
*Keep width of pedestrian mode, cancel auto-close function of pedestrian mode: Please
turn on the first and the second DIP switch (See Fig.7 No.18) to ON position. Press
button 4 to open the gate (see Verify open direction section). Wait some seconds (3~10
sec.), then press the same button/button 4 to stop the gate. Wait until the gate close
automatically (45 sec.). Press the same button again to stop the gate or the gate will stop
automatically at its closed position if the magnetic limit switch is reached. After this setup
is complete, return DIP switch 1 to OFF position immediately. Thus the width of
pedestrian mode has been reserved, the auto-close function of pedestrian mode has
been canceled.
Note: the new width of pedestrian mode has been re-programmed in the device and
replaced the original width.
If you open the gate with button 4, the gate will stop at the expected position that you
have set, but the gate will not close automatically.
Turn on the second DIP switch to OFF position (Factory preset: OFF position), both auto
close function and auto-close function of pedestrian mode were shut off.
Safe guard (Infrared device): If the infrared beam is broken during closing, the gate will
reverse and open immediately. The control box is not factory equipped with an infrared
device.
Tuning the auto-reverse safety function: rotate the 'Force Adj. VR' knob (See Fig.7 No.7)
with a screwdriver. The resistance may be increased or decreased by rotating clockwise
or counterclockwise. NOTE: if the gate fails to reverse in the event of obstruction, then
the opening force or closing force should be checked for conformity with requirements
and adjusted accordingly. The gate will reverse if obstructed when closing, and will stop
if jammed when opening.
Please exchange wires 'V' and 'W' if the auto-reverse direction is wrong. Exchange wires
'OP' and 'CL' if the limit direction is wrong.
WARNING: Do not attempt to tune the gate by placing your hand, arm or other body part
in the path of the gate, as serious injury could result. Damage to the gate operator
motors may also occur by placing a heavy immovable object in the path during the
testing phase. Instead, place a light object in the path (e.g., a chair or trash can) which
can be pushed out of the way without causing damage to gate motors, if the setting is
still too high. Note: This auto reverse function should be regularly inspected and adjusted
if necessary. Once the tuning is complete you may replace the cover.
Activities Covered in this section
Remote control (Single-button mode): With each press of the button, the gate will
open, stop, close or stop cycle.
13