TROUBLESHOOTING
SYMPTOM
Tool runs at normal
speed but slows down
under any load.
Tool runs slowly. Air flows
weakly from exhaust.
Tool will not run. Air flows
freely from exhaust.
Tool will not shut off.
AIRLINE ACCESSORIES AND CONSUMABLES
A wide range of airline accessories is available including filter/regulators,
lubricators, high-pressure hoses (5 to 50 metres) etc. Contact your Clarke
dealer or Clarke International Service Department for further information.
Clarke Air-lne Oil (Part no. 3050825) is available from your Clarke dealer.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBLEM
1. Excessive pressure on
the sander.
2. Motor parts worn.
3. Worn or sticking
mechanism due to
lack of lubricant.
1. Motor parts jammed
with gum/dirt.
2. Regulator in closed
position.
3. General airflow
blocked by dirt.
1. Motor vanes stuck
due to buildup of
foreign material.
1. O-rings damaged or
ill-fitting in seat.
12
SOLUTION
1. Reduce the force
applied to the sander.
2. Return to Clarke dealer
for repair.
3. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
1. Examine inlet air filter for
cleanliness.
2. Adjust regulator to open
position.
3. Operate tool in short
bursts.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Tap motor housing gently
with a rubber mallet.
4. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving
parts.
1. Return to Clarke dealer
for repair.