Clarke 7260040 Handbuch - Seite 2
Blättern Sie online oder laden Sie pdf Handbuch für Water Pump Clarke 7260040 herunter. Clarke 7260040 2 Seiten. Submersible transfer pump
Auch für Clarke 7260040: Handbuch (4 seiten)
Limitations of Use
This pump is ONLY for use with the following:
•
Clean water or water with small solids in suspension (dirty water).
•
Diesel fuel
•
Paraffin
DO NOT use this pump for pumping:
•
Slurry
•
Septic tanks
•
Sandy water
•
WARNING: DO NOT USE FOR PUMPING PETROL
Safety Precautions
•
ALWAYS disconnect the pump from the power supply before performing any
maintenance.
•
ALWAYS check the power cable before use to ensure it is perfectly serviceable.
•
ALWAYS ensure the filter is clean and perfectly serviceable before use.
•
NEVER run the pump dry. Minimum water depth is 30mm.
•
DO NOT exceed the duty cycle - see Specifications.
•
DO NOT use if any part appears to be damaged. Have it repaired by your Clarke dealer.
•
DO NOT use the pump for any purpose other than that for which it is intended.
•
DO NOT operate the pump continuously - eg. in a fish pond or collection tank, water
feature etc.
•
DO NOT use or leave the pump in freezing conditions.
•
DO NOT allow uncontrolled discharge of contaminated water etc. ALWAYS collect in
a container and dispose of according to all H & S and local regulations.
Specifications
Flow Rate ..................................................... 16.5 litres/min
Min. Water Depth ....................................... 30mm
Voltage ........................................................ 12V
Current ......................................................... 4.5A DC
Pressure ........................................................ 15psi / 1 bar
Height ........................................................... 145mm
Diameter ...................................................... 53.5mm
Weight .......................................................... 0.6kg
Duty cycle ................................................... 15mins continuous in any
We declare that this product complies with the following EEC directive - 98/37EC
signed:
Mr D. Kemp, Engineering Mgr
30 min period
Dated 30 Nov 2007
Method of Operation
1.
Always check to ensure the pump is in perfect working order:
- has no apparent damage
- the filter is in place and is perfectly clean
- the power cable is in perfect condition
2.
Attach the flexible hose to the outlet, securing with the jubilee clip supplied.
3.
If required, attach the stainless steel tube to the discharge end of the flexible hose,
securing with the jubilee clip supplied.
4.
Carefully lower the pump into the pit or sump etc, to be drained.
IMPORTANT; if the bottom of the pit or sump is muddy or sandy, position the pump on a brick
or similar support. DO NOT allow it to rest in the mud or sand.
5.
Connect the clamps to the 12Volt battery and the pump will operate.
IMPORTANT: ALWAYS connect the red - positive clamp to the red positive terminal of the
battery FIRST, then connect the black clamp to the black - negative terminal, ensuring both
clamps are perfectly secure.
When disconnecting - ALWAYS disconnect the black - negative clamp FIRST.
Always observe the pump discharging. Should performance deteriorate during use, it is
probable that the filter is becoming blocked. In this case, disconnect the pump from the
battery - (black terminal first), then carefully remove the pump from the pit or sump etc. DO
NOT yank the cable.
Unscrew the base cap and remove the filter. Either clean thoroughly or replace as necessary,
then check the impeller to ensure it is free to rotate and is not blocked.
When satisfied, replace pump in sump or pit and resume pumping.
When finished ALWAYS remove the filter and clean thoroughly, then allow it to dry.
Thoroughly clean the pump with clean water and ensure the impeller is completely free to
rotate and is free of contaminants.
Reassemble the pump and store in a clean dry environment.
Parts and Service
The following parts are available from your Clarke dealer
1.
End Cap
2.
Filter
3.
Cable Clamp - Red
4.
Cable Clamp - Black
5.
Flexible Hose - 4M
For Spare Parts and Service, please contact your nearest dealer,
or CLARKE International, on one of the following numbers.
PARTS & SERVICE TEL: 020 8988 7400
PARTS & SERVICE FAX: 020 8558 3622
or
e-mail as follows:
PARTS: [email protected]
SERVICE:
Part No:
MSP1201
MSP1202
MSP1203
MSP1204
MSP1205