Directed Electronics IntelliGuard 7000 Installationshandbuch - Seite 11

Blättern Sie online oder laden Sie pdf Installationshandbuch für Autoalarm Directed Electronics IntelliGuard 7000 herunter. Directed Electronics IntelliGuard 7000 16 Seiten. Car security system intelliguard 7000

Directed Electronics IntelliGuard 7000 Installationshandbuch
To access the installer-programmable features, use the procedure defined in the User-Programmable section, but in step 4, hold and
press the
side of the PlainView 2 Switch for 15 seconds. You will hear three confirmation chirps indicating that the system is in
installer-program mode.
Table of Installer-Programmable Features (1 chirp = OFF, 2 chirps = ON)
Fea ture
Unmarked 1
Select
Single/Double Lock Pulse
1
(1 chirp/2 chirps)
Single/Double Unlock Pulse
2
(1 chirp/2 chirps)
Lock/Unlock Pulse
3
3 second/1 second
(1 chirp/2 chirps)
Program Door Polarity
4
(Positive/Negative)
(1 chirp/2 chirps)
Program RPM
See Mandatory RPM
5
Programming section in this
Aux il iary Si ren Out put
6
(Constant/Pulsed)
(1 chirp/2 chirps)
Once this feature is selected, one chirp is provided to indicate that the timer has started. You can set this anywhere
n
NOTE 1:
from one second to four minutes. When the desired duration has been reached, press the unmarked side of the PlainView 2
switch. The system responds with two chirps to confirm the new system timer duration.
The fol low ing check list and trou ble shoot ing tips will as sure that you have in stalled the IntelliGuard 7000 cor rectly. If the sys tem does
not re act as noted, fol low the trou ble shoot ing tip(s) de noted with a black box be low that item, then re peat the step. Each suc ces sive
step re quires that the pre vious step has been com pleted as in di cated.
The CliffNet Wizard simplifies the troubleshooting process by providing system diagnostic information in a graphical format. All
system settings are provided at-a-glance, and adjustments to the system settings can be made with a click of a mouse. This reduces
the amount of time required for performing the following tests.
Step 1.
Re- enable the cour tesy lights.
In step 1 of the Important Information sec tion in this binder, the in te rior cour tesy lights were disabled. You must now re-enable
the courtesy lights by re placing the fuse you re moved or re set the cour tesy light switch back to its nor mal "DOOR" po si tion bef ore
pro ceed ing.
In tel liGuard 7000/199

Installer-Programmable Features

Unmarked 2
Accessory Output Timer
Duration
(10 seconds)
See NOTE 1
Auxiliary A Type
(Pulsed/Timed/Latched)
(1 chirp/2 chirps/3 chirps)
Auxiliary BType
(Pulsed/Timed/Latched)
(1 chirp/2 chirps/3 chirps)
Auxiliary CType
(Pulsed/Timed/Latched)
(1 chirp/2 chirps/3 chirps)
Diesel Engine/Gas Engine
(1 chirp/2 chirps)
(For IntelliStart 4 only)
binder
NOT USED
System Checklist & Troubleshooting
Unmarked 3
Door Ajar Warning/Delayed
Courtesy Lights
(1 chirp/2 chirps)
Auxiliary A (trunk release)
Interlock
(On/Off)
Auxiliary B Interlock
(On/Off)
Auxiliary C Interlock
(On/Off)
AutoActivate Auxiliary C upon
Remote Arming
(On/Off)
Learn PageMate 4 ID or
Program SmartWindows 4
(Requires Optional
SmartWindows 4)
11