Clarke PSP105 Handbuch für Betrieb und Wartung - Seite 6
Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Water Pump Clarke PSP105 herunter. Clarke PSP105 13 Seiten. 250w puddle pump with auto sensor
MANUAL OPERATION
The pump can also be switched on
manually by inserting the sensor into
the socket on the side of the pump.
NOTE: If the sensor is inserted into the
socket, the pump will run
continuously.
NOTE: Do not allow the pump to run
dry.
POSITIONING THE PUMP
1. Place the pump on a flat surface in the area that you want to drain.
• If there is sediment in the operating area, the pump should be placed
vertically on house bricks, or similar.
• ALWAYS raise and lower the pump using a rope attached to the lifting
handle.
• Take all necessary precautions as described on page 3.
USING THE PUMP
WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE
PUMP IF IT IS DAMAGED IN ANY WAY.
1. Connect the mains plug to the mains supply.
• Always use a high sensitivity residual current device (RCD) which has a
tripping current of less then 30mA.
2. Switch the mains power supply on.
• The pump will begin to drain water.
3. When pumping is finished, disconnect the pump from the mains power
supply.
IMPORTANT: During manual operation, do not allow the pump to run dry.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]