Clarke Strong Arm CS10PRH Betriebs- und Wartungsanleitung - Seite 7

Blättern Sie online oder laden Sie pdf Betriebs- und Wartungsanleitung für Water Pump Clarke Strong Arm CS10PRH herunter. Clarke Strong Arm CS10PRH 13 Seiten. 10 tonne hydraulic pump, ram & hose

Clarke Strong Arm CS10PRH Betriebs- und Wartungsanleitung

MAINTENANCE

If the pump has been stored for long
periods, check the oil level before use.
Stand the pump on a level surface
and remove the breather valve on the
oil reservoir. If necessary, top up via
the breather valve which is then
screwed on finger tight.
Note: Only unscrew this when the
system is not under pressure.
The oil level should be near the
bottom of the opening. If required, oil can be topped top using Clarke
Hydraulic Oil. (part no. 3050830 for 1 litre).
After extensive use, the hydraulic oil should be replaced to ensure longer
equipment life. Do not overfill, or the piston rod will be unable to move freely.
Replace the breather valve after re-filling. The required oil volume is 500 ml +
5ml.
STORAGE
After use, screw the valve cover on to
the pump to keep the connection
clear of dust and dirt and cover the
hydraulic hose end with the plastic
cap.
When not in use, the pump should be
stored with the release valve open.
Store all the equipment in its case in a
clean, dry environment protected
from the weather.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for its intended purpose.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission. This guarantee does not effect
your statutory rights.
Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]
Breather valve
Valve Cover
7
Hose end cap