Description
Preset metered valves are designed to
dispense preset quantities of fluid lubricants.
Each model is equipped with an inlet swivel,
a high-volume manual nozzle, and rigid or
flexible extension.*
The models differ in the units of measure
that are metered and the face dial range
(³ Table 1 for details).
A totalizer keeps a lifetime record of the
amount dispensed in a unit of measure
labeled on the dial.
These models are also equipped with an
internal filter screen to prevent damaging
contaminants from entering the meter.
Operation
1 Turn pointer counterclockwise to
required quantity of fluid to be
dispensed.
2 To dispense, depress lever until it locks.
Lever disengages automatically once
preset amount is delivered.
Emergency release
mechanism
To stop preset delivery before completion,
move lock pawl to right (³ Fig. 1). This
releases the lever and stops delivery.
NOTE
Do not turn pointer clockwise.
Failure to comply may result in
damage to equipment.
*
Indicates change.
Preset metered control valve models 3690-C, 3690-D*, 3691-C, 3693-C, 3696-C
Valve model
Inlet
-C
/
in NPTF
1
2
(internal)
-D*
/
in NPTF
1
2
(internal)
-C
1
/
in NPTF
2
(internal)
-C
/
in NPTF
1
2
(internal)
-C
/
in NPTF
1
2
(internal)
*
Indicates change.
Preset metered control valve
1)
)
Lock pawl
Register units
Current (w/range)
Totalizer
Accuracy
Quart ( 60)
Gallon
± .%
Quart ( 60)
Gallon
± .%
Gallon ( 15)
Gallon
± .%
Liter ( 60)
Liter
± .%
Quart ( 16)
Quart
± .%
A
Table 1
Maximum pressure
psi (69 bar)
psi (69 bar)
psi (69 bar)
psi (69 bar)
psi (69 bar)
Fig. 1
A