Directed Electronics Xpresskit Solex PLJX Installationshandbuch - Seite 4

Blättern Sie online oder laden Sie pdf Installationshandbuch für Zubehör für Kraftfahrzeuge Directed Electronics Xpresskit Solex PLJX herunter. Directed Electronics Xpresskit Solex PLJX 9 Seiten.

Directed Electronics Xpresskit Solex PLJX Installationshandbuch
MODEL: pljx

ION TYPE PASSLOCK PROGRAMMING

STEP 1- PASSLOCK TYPE SELECTION
ION type Passlock is the default setting. Verify by checking
jumper settings on the module. If installing on an ION type
Passlock system skip to "Step 2" after connecting the
Passlock wires.
*If you are installing on a vehicle equipped with either
Passlock 1 or Passlock 2 or VATS you must change
Passlock Type before you can program resistor code.
(go to Passlock Type Selection on page 2).
STEP 2- PROGRAM RESISTOR CODE
(For manual transmission vehicles, put shifter in the NEUTRAL position
and DO NOT PRESS CLUTCH when doing STEP A & B)
Start vehicle by key & HOLD in the START position. Do not release until
A)
programming is complete.
(Vehicle will NOT over crank.)
Press & hold the programming button. LED will come on solid, then
B)
start to flash rapidly. Continue holding the button. Once the LED stops
flashing, and returns to a solid LED, release button and turn the ignition
to the OFF position.
C)
Passlock resistor Code is now programmed, connect brown wire to
ground when running (status) output from remote starter and test
bypasskit function by remote starting the engine.
NOTICE
In case of component failure, it is likely that the
GM Passlock will enter into "Long Tamper" mode.
This will prevent the vehicle from starting for a
period of 10 minutes. In this event, turn key to the
"ON" position and let vehicle rest until the
GM Security light stops flashing.
Connect Brown wire to remote starter only after
RESISITOR CODE programming is complete.
© 2011 Directed Electronics. All rights reserved.
Rev.: 20111017