Blower Inspection and Maintenance
Periodic blower maintenance is required for reliable continuous operation. Any maintenance of the blower other than those described
herein this manual must be performed by an authorized service provider.
NOTICE: Always turn off the power and unplug from electrical terminal before any maintenance. Failure to observe this precaution
can result in a serious accident.
Air Filter
Air filter, located under the filter cover, should be inspected and cleaned every 3 to 6 months. Wash the filter pad gently in mild, soapy
water then rinse thoroughly. Allow filter pad to dry completely before reinstalling.
Diaphragm
Diaphragm module replacement is typically recommended for every 24 months of operation. Replacement cycle may differ from
application to application, it is prudent to perform the replacement before any actual diaphragm failure. Diaphragm replacement kits
are available.
1.
Set blower upside down (remove filter cover for stability if needed), unscrew and remove all upper housing screws. Return blower
to upright position and lift away upper housing. Number of housing screws: AL-100 ~ 200 (6x).
2.
Detach the L-tube from discharge port of each diaphragm housing.
3.
Select a diaphragm housing on core frame, remove its 4 corner screws, and then pull housing away. Proceed to remove the hex
nut and washer from center of the diaphragm then pull and slide the entire diaphragm block away from magnetic rod and core
frame.
4.
Select a new diaphragm block from the replacement kit, align shape with core frame and magnetic rod then slide over the rod
screw. Secure assembly firmly with washer and hex nut. Apply 1 to 2 drops of removable grade thread locker between the hex
nut and protruded rod screw.
5.
Install new diaphragm housing then secure with 4 corner screws.
6.
Attach L-tube to the discharge port of the new diaphragm housing then secure with silicone band or wire hose clamp.
7.
Repeat step #3 through #6 on opposite side. IMPORTANT: Do not mix old and new parts. For reliable operation, always replace
both diaphragm modules in the blower at the same time.
8.
If the blower includes a protective switch on top of the blower core, rotate and reset the switch to ON position.
9.
Install upper housing and secure firmly with all housing screws.