Clarus Technologies WCS-25 Benutzerhandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Reinigungsgeräte Clarus Technologies WCS-25 herunter. Clarus Technologies WCS-25 16 Seiten. Cleaning stations
Auch für Clarus Technologies WCS-25: Benutzerhandbuch (14 seiten)

Clarus Technologies WCS-25 Benutzerhandbuch
appropriate setting. When the proper amount of air is achieved, push knob down to lock
your setting. With this set-up, air will always be available at the nozzle.
Agitation Tank/Pump Assembly
The PCS/RPW-25 and PCS/RPW-15 can be equipped with an optional stainless steel
soak tank ("Soak Tank") and a UL-approved submersible agitation pump.
"ON/OFF" switch for the Soak Tank is located on the left side of the lid. The switch may
be located on the right side of RPW models not equipped with an optional halogen light.
Prior to turning the agitation on:
1) Place the stainless steel tank along the left hand side wall of the working surface,
2) Turn on the Solvent Flow Switch. As the solvent begins to flow, use the
cleaning brush and/or nozzle to fill the stainless steel soak tank until it covers the
pump.
3) Once the soak tank is full you can turn on the pump. The agitation pump will
stay on until it is manually turned off.
Fluid Nozzle – shutoff
E.
(PCS/RPW parts cleaning models only) The fluid nozzle flow can be adjusted or turned
off by turning the yellow valve handle at the nozzle's base.
F.

Filter Differential Pressure Gauge

(Standard on PCS/WCS; Optional on RPW/RWC models). The PCS/WCS models use a
pressure gauge to indicate when the filters need replacing. This is an optional feature in
the RPW/RWC models. Replace filters when the gauge reads 40 PSI. Operating system
beyond 40 PSI will not damage the unit; however, the quality of the solvent will degrade
beyond 40 PSI.
G.

Fusible Link

The OSHA Regulated Fusible Link that holds the lid open will release the lid if the
ambient temperature reaches 165 F. Never bend the Fusible Link, as this will weaken
it.
WARNING!
Do not coat or paint fusible link as this may prevent proper
operation. Inspect fusible link annually and replace if corrosion and/or stress is
evident.
J.

Leveling Bolts

The front two legs contain bolts, which are used to minimize any rocking from uneven
floors, and will aid in leveling the unit. The unit must be level to work properly.
The
10