5- Check that the adapter is correctly placed and tightened where it connects to the brake fluid jar.
If the brake fluid leaks, stop the device immediately and look for the cause of the leak.
6- Now, bleed the brakes, one by one, starting with the right rear brake and ending with the left
front brake.
To do this, open the bleed screw at the wheel and connect the recovery bottle to it. Recover used
brake fluid using it (if necessary, CLAS offers a variety of bottle, jerry can recovery www.clas.com)
As soon as the new (clear) bubble-free brake fluid begins to flow through the drain hole, the bleed
screw can be closed again.
7- Set the «ON/OFF» switch to «OFF»
8- Check on the pressure gauge that the pressure has dropped to 0 bar.
Note :
Usually the brake maintenance device automatically gets rid of the remaining pressure. However, if
during the refilling process, the pressure was regulated lower, there will still be pressure remaining.
The pressure does not go down to O bar. The pressure regulator must be unloaded first. After
turning off the device, turn the pressure regulator to the right until the release point for the
remaining pressure is reached. The working pressure drops to O bar.
9- Uncouple the depressurized filling hose from the adapter. Remove the adapterfrom the brake
fluid reservoir.
Important :
After completing the bleeding process or exchanging brake fluid, should the operation of the brake
or clutch pedal be too long or the pressure behind the operation be to «soft», repeat depressing
the pedal several times, each time applying stronger pressure to the pedal or clutch. If the situation
remains unchanged, the bleeding procedure needs to be carried out again.