TROUBLE SHOOTING GUIDE
NOTE :- Check all solutions before dismantling the pump.
PROBLEM
Pump will not start
Erratic flow
Pump strokes but will not
discharge
Fluid discharged from air
exhaust
Intermittent stroke rate
FLUID CONNECTIONS
1" BSP (F)
1" ANSI 150 FLANGE
MAX. WORKING PRES-
SURE
7.0 Bar (100 psi)
For overall dimensions see page 7
HG-CF-1101 Rev. C – 19.05.06
Trouble Shooting Guide & Technical Data
Air valve assembly malfunction/Seizure
Obstructed fluid line.
Obstructed diaphragm chamber.
Diaphragm failure causing fluid & excessive air to be
expelled through the exhaust.
Diaphragm seal failure.
Air valve system malfunction.
Air connected to exhaust.
Diaphragm failure on one side.
Valve ball not seating.
Suction leakage.
Diaphragm failure causing fluid & excessive air to be
expelled through the exhaust.
Diaphragm seal failure.
Air valve system malfunction.
Excessive suction lift.
Suction line leakage.
Valve ball not seating correctly or damaged.
Suction line or strainer clogged.
Diaphragm failure.
Diaphragm Failure.
Loose frontplate.
Over lubrication
Diaphragm shaft seal failure.
Air valve system malfunction.
Valve ball not seating / partially obstructed.

TECHNICAL DATA

CAPACITY
0 - 136 Litres/Minute
(0 - 30 Gallons/Minute)
AIR INLET
3/8" BSP (F)
3/8" NPT (F)
CAUSE
MAX SOLIDS
MAX DISCHARGE HEAD
3 MM
(1/8")
TEMPERATURE LIMITS
0
100
C PTFE & Conductive PTFE
SOLUTION
Check carrier for freedom of movement. -
Clean, oil & replace.
Clean line or increase line size.
Remove obstruction.
Replace diaphragm.
Replace shaft seals.
Check all seals in valve chest assembly.
Re-connect to air inlet.
Replace diaphragm.
Check and remove obstruction.
Check and correct.
Replace diaphragm.
Replace shaft seals.
Check all seals in valve chest assembly.
Shorten suction line.
Check and correct.
Check and remove obstruction / replace.
Clear.
Replace diaphragm.
Replace diaphragm.
Re-Torque to manual specifications.
Shut-down pump. Remove air connection
into pump & introduce a small quantity of de-
greasing agent into air valve and replace
line. Run pump until clear.
Replace seals.
Check all seals in valve chest assembly.
Clear obstruction.
70 Meters
(230 ft)
PUMP WEIGHTS :-
DISPLACEMENT
PER STROKE
0.475 Litres
(0.1 UK Gallons)
T5 : 37 Kg
44 : 40 Kg
Page 5