To identify charge circuit damage, the battery terminal voltage jumps up to the charge voltage while the app shows
no current and a much lower voltage, the exact discrepancy depends on the actual block voltage.
It is normal to have a small discrepancy between terminal and battery voltage shown in app during normal
operations.
SoC is inaccurate:
Lithium batteries have a flat discharge curve making it necessary to estimate SoC based on an algorithm considering
numerous present data points and historical usage factors. Low currents and usage. parasitic draws, may result in an
inaccurate SoC calculation.
To reset the SoC calibration please refer to CSB 855-0014 Lithium BLUE – SOC Calibration
https://assets.discoverbattery.com/documents/dl_blue/csb-dlb-soc-calibration.pdf.
Customers with multiple batteries may benefit from using an external SoC gauge (such as Victron).
Battery Voltage
12V
24V
36V
Positive terminal deformation / melting of cover
Refer to CSB 855-0012 DLB 12V Positive Terminal Overheating
https://assets.discoverbattery.com/documents/dl_blue/csb-dlb-12v-positive-terminal-overheating.pdf.
For other issues or additional support, please submit a support request at:
https://discoverbattery.com/contact/contact-support.
CUSTOMER SERVICE BULLETIN
Reference SoC Voltages
0% SoC
20% SoC
80% SoC
12.0V
~12.8V
~13.3V
24.0V
~25.6V
~26.6V
36.0V
~38.4V
~39.9V
- End of Document -
100% SoC
>=13.6V
>=27.2V
>=40.8V
Page 2 of 2
F orm: 880-0012 Rev A