Technical data

PROSTR5S, PROSTR10S - Solo starBOX
Antenna inputs
Signal frequency ranges
Gain or loss to MASTER OUT
VHF bypass to distribution outputs 2dB gain
Max. recommended input level
Input filter rejection
Line power for UHF preamplifier
LNB 2 input
Insertion loss to LNB 2 OUT
Filter rejection
Line power pass
Distribution section
Signal frequency range (UHF)
Number of distribution outputs
Gain to distribution outputs
Max. recommended input level
RF return path frequency range
Remote control compatibility
IR receiver (eye) line power
General
Mains power requirement
Signal connector type
Operating temperature range
Standards compliance
Notes:
1. CCTV IN is an auxiliary UHF input and can be used for any UHF (modulated) signal source. This input
should always be terminated in 75Ω if no used (a suitable termination is supplied with each unit).
2. Maximum UHF signal levels are given for 5 analogue TV channels plus up to 6 DTT multiplexes at ≤ -
14dB relative level (FM RADIO SIGNALS SHOULD NOT EXCEED –10dB relative to analogue TV).
3. For all frequencies ≤ 400MHz (TETRA filtering).
4. For all frequencies ≤ 854MHz (LNB wideband noise filtering).
5. Recommended preamplifier is PROception type PROMHD11L (use only in weak signal areas or
where there is a long cable run from the UHF antenna.
* Sky and Sky+ are registered trademarks of British Sky Broadcasting Group PLC.
Freeview is a registered trademark of DTV Services Ltd.
FM ANT IN DAB ANT IN
87.5 ..
217.5 ..
108MHz
230MHz
8dB gain
8dB gain
2dB gain
2
66dBμV
60dBμV
-
-
5
-
-
2dB (950 .. 2150MHz)
4
≥ 23dB
20V DC at 250mA max. (also applies to MASTER OUT to LNB 1 IN)
470 .. 862MHz (via UHF RETURN IN)
5 (PROSTR5S) or 10 (PROSTR10S)
4dB
75dBμV
5-10MHz (gain approx. 2dB from each distribution o/p to UHF RETURN IN)
PROSAT1EYE (IR control eye 'magic eye')
9V DC at 15mA present at all distribution outputs
230V 50Hz at 8W (10VA)
F' (IEC 60169-24)
-10 .. +40°C
Safety: BS EN 60065 : 2002; EMC: BS EN 50083-2 : 2001 - equipotential
bonding terminal provided
CCTV IN
(UHF)^1
UHF ANT IN
470 ..
470 ..
862MHz
862MHz
8dB loss
13dB gain
-
-
.- (passive)
76dBμV
3
-
≥ 26dB
-
8V at ≤ 25mA -
LNB 1 IN
950 .. 2150MHz
2dB loss
-
.- (passive)
4
≥ 43dB