ARP Fridge Defend Benutzerhandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Zubehör für Kraftfahrzeuge ARP Fridge Defend herunter. ARP Fridge Defend 10 Seiten. V5 + fan control
Auch für ARP Fridge Defend: Gebrauchsanweisung (17 seiten)
ARP Control v5.x
On/Off
Display
On/Off
Display
User Manual 04/20/2020 © ARPC L.L.C. All rights reserved.
1.7 Controller Function Test
This is an automated test, when
test is being preformed. To meet IEC Design standards,
the v5.1 control has an alarm that alerts the operator
that there is a critical system failure, the alarm will
sound during this test (v5.0 omits this function for
economy). The operator must hear the audible alarm
during this test for the v5.1. When the test finishes, one
of two events will occur:
If the test passes,
button to exit the test. The center dot will resume
flashing to indicate that the control is returned to the
ARP Control mode.
If either the
contact ARP & discontinue use of controller.
1.8 ARP Protection Period (What are the
numbers on the display?)
When the ARP Control detects an overheat situation,
the control turns off the refrigerator and starts a
countdown period. The countdown period is the time
until the ARP attempts a safe restart of the refrigerator.
SetUp
Control during this protection period. Allow the Fridge
Defend to do its job, otherwise damage may occur.
One of three events will occur at the end of the
countdown period:
1) If the boiler has cooled enough, the control will
restart the refrigerator & center dot will resume flashing.
2) If the temperature is still too high to restart the fridge,
000
SetUp
1.9 Rapidly Flashing
If the control turns off the refrigerator 5 times in a row,
the ARP will turn off the refrigerator and rapidly flash
*O*F*8
off the ARP. For the v5.1 control, an audible alarm will
sound alerting the operator that the fridge has an error.
Please consult an RV repair facility to restart your
fridge if this event occurs. Please see next 2 sections
and Troubleshooting Guide for further details.
PAS
F4
or
F5
error message is displayed,
WARNING: Please do not turn off the ARP
will flash until it is safe to restart the fridge.
until the operator resets the control by turning
tSt
is displayed the
will display, use the SetUp
*O*F*8
3