PROGRAMMING
DESCRIPTION OF THE COMMANDS
8
8
Display
 To enter the menu, keep the ENTER button
pressed for at least one second.
8
8
FUNCTIONS MENU
Warning! When programming, the gate must not be operating.
F1 Total stop (1-2)
NC input – Gate stop that excludes any automatic closing; to resume movement, use the control device. The safety device is inserted into (1-2).
F2 Input (2-CX)
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges (with clean contact), C8 = reclosing during opening by sensitive safety-
edges (with clean contact), r7 = reopening during closing for sensitive safety edges (8K2 resistive input), - r8 = reclosing during opening for
sensitive safety edges (8K2 resistive input).
 The C3 Partial stop function only appears if the F 19 Automatic closing time function is activated.
F3 Input (2-CY)
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges (with clean contact), C8 = reclosing during opening by sensitive safety-
edges (with clean contact), r7 = reopening during closing for sensitive safety edges (8K2 resistive input), - r8 = reclosing during opening for
sensitive safety edges (8K2 resistive input).
 The C3 Partial stop function only appears if the F 19 Automatic closing time function is activated.
F5 Safety test
After every opening or closing command, the board will check whether the photocells are working properly.
 The safety test is always active for wireless devices.
8
8
8
8
1"
OFF (default) / ON
OFF (default) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7 / 8 = C8 / r7 = r7 / r8 = r8
OFF (default) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7 / 8 = C8 / r7 = r7 / r8 = r8
OFF (default) / 1 = CX / 2 = CY / 4 = CX+CY
The ESC button is for:
{
- exiting menus;
- cancelling changes;
- stopping the gate (only when testing).
{
The < > keys are for:
- moving from one item to another;
- increasing or decreasing a value;
- opening and closing the gate (only when testing).
{
The ENTER key is for:
- entering menus;
- confirming or memorizing set values.
To exit the menu, wait 10 seconds or press ESC.
8
8
8
10"