Dimensions and basic measurements
General installation indications
⚠ Only skilled, qualified staff must install this product.
Preliminary checks
⚠  Before beginning, do the following:
• check that the gate structure is sturdy enough, the hinges work efficiently and that there is no friction between the fixed and moving parts;
• if ground stops are not, or cannot be, fitted, use the supplied mechanical stops;
• make sure that the point where the gearmotor is fastened is protected from any impacts and that the anchoring surface is solid enough;
• make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules. It should
completely cut off the power supply according to category III surcharge conditions (that is, with minimum contact openings of 3 mm);
make sure that any connections inside the container (ones that ensure continuity to the protection circuit) are fitted with additional insulation
with respect to those of other electrical parts inside:
set up suitable tubes and conduits for the electric cables to pass through, making sure they are protected from any mechanical damage
Tools and materials
Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable regulations. The figure
shows some of the equipment installers will need.
Cable list and minimum thickness
Connection for
230 V power supply to control panel
Motor power supply (V) 24 V
Flashing light
Photocell transmitters
Photocell receivers
Accessories power source
Safety and command devices
Antenna
N.B. If cables are of a different length than that shown in the table, determine the cable section based on the actual draw and the
number of connected devices and according the what is set forth in the CEI EN 60204-1 code of regulations.
For connections featuring several loads on the same line (i.e. sequential ones), the dimensions shown on the table must be
reconsidered according to the total draw and actual distances. When connecting products not featured in this manual, only refer
to the literature accompanying such products.
194
Cable length
Cable type
1 < 10 m
3G x 1.5 mm
3 x 1 mm
FROR CEI
2 x 0.5 mm
20-22
2 x 0.5 mm
CEI EN
4 x 0.5 mm
50267-2-1
2 x 0.5 mm
2 x 0,5 mm
RG58
245
218
Cable length
10 < 20 m
2
3G x 2.5 mm
2
3 x 1.5 mm
2
2 x 1 mm
2
2 x 0.5 mm
2
4 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
max. 10 m
Cable length
20 < 30 m
2
2
3G x 4 mm
2
2
3 x 2.5 mm
2
2
2 x 1.5 mm
2
2
2 x 0.5 mm
2
2
4 x 0.5 mm
2
2
2 x 1 mm
2
2
2 x 0.5 mm