6
ON Blink OFF OFF a) PHIRE-FG no power
7
ON OFF Blink Blink a) Pixel clock out of operating
8
ON Blink Blink Blink a) Fiber cable is not fully
9
PHIRE system
functions normally
but no clear image

8. Product Safety and Regulatory Compliance:

8.1. Product Safety:

The fiber optical adaptors are designed and categorized as a Class 1 Laser product. ALWAYS
avoid viewing directly into the optical ports, as the laser will cause serious damage to eyes. It is
also recommended to connect the fiber cables before power-on the PHIRE system.

8.2. Regulatory Compliance:

Our products have been tested and found to be compliant with the following standards:
FCC, Part 15, Class A
AZ/NZS 3548: 1998
EN55022 for Electromagnetic Emission
EN55024 for Electromagnetic Immunity
EN60950 for Low Voltage
The AC/DC power adaptors provided and the optical transceivers are compliant with applicable
CE directives and FCC standards by the original manufacturers.
D-A-CH
FrAnCe – Telecom
Phrontier Technologies
Laser 2000 GmbH
Laser 2000 SAS
82234 Wessling
78860 St-N. l. Bretèche
Tel. +49 8153 405-0
Tel. +33 1 30 80 00 60
www.laser2000.de
www.laser2000.fr
b) Fuse burn off on the FG
module, possible causes
including current or voltage surge
from direct DC power on or due
to improper electrical grounding.
range
engaged
b) Fiber connector end facet is
contaminated
c) Optical I/O port is obstructed
by foreign objects
d) Fiber cable breakage
a) Incompatible camera and
frame grabber

Table 4 Trouble Shooting Procedures

FrAnCe – Photonic
PHIRE User Manual V4
Laser 2000 SAS
33600 Pessac
Tel. +33 5 57 10 92 80
www.laser2000.fr
a) Check PHIRE-FG power connection
and reset camera and PHIRE system
b) Send back the unit to Phrontier Tech
or authorized distributors for fuse
replacement
a) Verify camera pixel clock output within
the operating range of selected model
a) Inspect/secure fiber cable connection
b) Use cotton sticks with alcohol to clean
the fiber connector ends
c) Make sure the unit is power off before
inspecting the optical I/O port
d) If foreign objects are found in the
ferrule, use tweezers to take out the
object
e) Do not use cotton sticks to clean the
optical I/O. This could leave fiber debris
inside the ferrule and cause more
problems
f) Use a known good fiber cable to test
PHIRE system's functionality.
a) Test system compatibility before
installing PHIRE
IberIA
Laser 2000 SAS
28034 Madrid
Tel. +34 617 308 236
www.laser2000.es