Description

The CMC-250 Circulating System is designed in accordance with API 8.3, to collect, store, and
mix sampled product from a sampling device such as the True-Cut C sampler.
The system consists of a stainless steel ASME code stamped receptacle with a quick-release
lid, a 1/2-hp explosion proof motor, a circulating pump, and a stainless steel in-line static
mixer, all mounted on an epoxy-coated steel skid. The receptacles are available in 5- and 10-
gallon sizes. Systems are available for standard duty, severe duty, and offshore applications.

Installation

1. Position the CMC-250 Circulating System upright and as close to the sampler device as
possible.
2. Confirm that the piping connections slope downward from the sampling device into the
receptacle.
3. Connect the drain valve to a sump or back into the pipeline.
NOTE: Pipeline pressure must be less than 100 psi when returning collected sample back into
the pipeline.
4. Install the ON/OFF Switch (supplied by customer) near the CMC-250 Circulating
System.
5. Check all electrical connections. All field wiring must conform to the National Electric
Code, NFPA 70. Local wiring ordinances may also apply. This equipment is for use in
non-classified areas only.
6. The motor is wired to turn in a counterclockwise direction at the factory. Refer to field
wiring instructions on the back of the electrical cover on the motor.

Startup Procedures

Perform the following steps before operating the CMC-250 Circulating System. Components
are identified by item number in the assembly drawing and Bill of Materials on page 3.
1. Ensure that the motor is OFF.
2. Secure the quick-release cover.
3. Close the drain valve (item 13B).
4. Close the sample draw-off valve (item 8).
5. Open the pump isolation valve (item 13C) and the recirculation valve (item 13A).
6. Close the drain valve (item 13B).
CMC-250 Circulating System
3
December 2006