ESE ES-562U Handbuch für Betrieb und Wartung - Seite 3

Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Zeitschaltuhr ESE ES-562U herunter. ESE ES-562U 7 Seiten. Combination clock / timer

The ES-562/564U is based on a single micro-processor chip, timer IC, Z4. A +5 volt DC supply consisting
of T1, diodes D1-D3, capacitors C1-C6 and regulator Z2 power it. T1 provides 6 VAC to the voltage
doubler circuit composed of D1-D2, C1-C4. Approximately +12 to +15 volts DC is developed across C1
and C3, which is regulated to 5 volts by Z2. This is used to power the clock/timer logic. A separate 6 VDC
supply is used to supply the segment driver chip Z6. IC Z4 provides all timing and control functions and
generates serial control signals for the display driver chips, Z6 and Z7. The display operates in multiplex
mode. Z6 and Z7 receive segment and digit drive data from Z4 via a data line (Z4 pin 28), a clock line (Z4
pin 27) and a strobe line (Z4 pin 26). A 50 or 60 Hz clock signal is taken from T1, logic-level converted by
Q1 and used for the counting timebase. Z4 also provides the optional Serial Timer Code, which is buffered
by IC Z3.

CIRCUIT DESCRIPTION

ES-562/564U Option "R" Connector Designations (DB9)
Pin
1
2
3
4
5
6
7
8
9
ES-562/564U Front View
UP
TIMER
DOWN
12 59 59
Function
Select/Reset
Set/Stop
Up
Down
Clock
Timer
Relay Contact (optional)
Relay Contact (optional)
Ground
SET
SELECT
CLOCK
STOP
RESET