Divus Heartbeat Schnellstart-Handbuch - Seite 4

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Netzwerk-Hardware Divus Heartbeat herunter. Divus Heartbeat 8 Seiten.
Auch für Divus Heartbeat: Schnellstart-Handbuch (9 seiten)

CLIENT SETUP

OPTIMA
TOUCHZONE
1.
Connect the TOUCHZONE(s) using one of the 8 ports of
the DIVUS MANAGED SWITCH.
2.
In the OPTIMA App's settings, use divus-heartbeat as KNX
SERVER IP address port number 3000
3.
Use the new DIVUS App DIVUS HEARTBEAT to see and
change the DIVUS heartbeat's settings, watch the logs,
scan the network etc.
iOS & Android devices
KNX SERVER IP ADDRESS FIELD (OPTIMA App):
dhb-heartbeat
PORT FIELD (OPTIMA App):
VIDEOPHONE (INTERCOM)
For any version of the DIVUS VIDEOPHONE: (iOS & Android devices)
VoIP SERVER IP ADDRESS FIELD:
dhb-heartbeat
DIVUS KNX SERVER / KNX SUPERIO v. 2.2+
Only change to the KNX SERVER settings:
1.
If you are using a KNX SERVER or KNX SUPERIO with
a fixed IP address, switch from STATIC to DHCP in the
network settings page and save. Otherwise or if you
bought the KNX SERVER/KNX SUPERIO together with the
DIVUS HEARTBEAT, go directly to point 2.
IMPORTANT NOTE:
PLEASE DO NOT USE THE IP ADDRESSES OF THE SERVERS IN THESE CONFIGURATIONS! USING dhb-heartbeat ALLOWS THE SYSTEM TO ADAPT TO
NETWORK CHANGES IN THE FUTURE AUTOMATICALLY, WITHOUT THE NEED TO RE-CONFIGURE ANYTHING.
NOTE: IF YOU CHANGED THE NAME dhb-heartbeat DURING THE FIRST SETUP, YOU MUST USE THE NEW ONE.
3000
FOR OTHER CLIENTS (SUPERIO, MIRROR, DIVA, laptops/PCs/
Macs etc.)
Please use dhb-heartbeat:3000 to load OPTIMA in a browser's
window. Use Google Chrome for best results.
SUPERIO and other Windows based Panels
URL (Browser):
dhb-heartbeat:3000
For https, substitute port 3000 with 3001
PORT FIELD (Videophone):
5060 (default SIP port)
2.
Connect to the DIVUS HEARTBEAT using a browser
on any computer connected to the DIVUS MANAGED
SWITCH (see FIRST SETUP) and make a scan. Wait for the
scan to complete.
3.
Then use the path shown above to connect from clients.