dixell COOL MATE XLH360 Betriebsanleitung - Seite 5
Blättern Sie online oder laden Sie pdf Betriebsanleitung für Temperaturregler dixell COOL MATE XLH360 herunter. dixell COOL MATE XLH360 16 Seiten. Cool mate temperature and humidity controller for seasoning-maturing cabinets
dIXEL
7. MATURING CYCLE WITH DRIPPING, RUNNING AND STOPPING PHASE.
Dripping
Running
The diagrams displays a typical maturing cycle with the starting dripping phase.
DRIPPING PHASE lasts for the "dri" time, without humidity control, temperature set is SETG
RUNNING PHASE lasts for the "on" time, both temperature and humidity are controlled.
STOPPING PHASE lasts for the "off" time, without any control of temperature and humidity.
The end of the stopping phase is signalled by the internal buzzer and by the "End" message on the display.
After the STOPPING PHASE the behaviour of the controller depends on the parameter trc, according to the following settings:
trc = co controller maintains the set points of the running phase
trc = in controller stop the regulation at all.
trc = cL controller performs the running and stopping phase till is stopped manually.
trc = cLE as (trc = cL) plus at the end of each cycle the End label is displayed and the buzzer is switched on.
7.1
HOW TO SET THE DURATION OF THE DRIPPING, RUNNING AND STOPPING PHASES
1.
Push the CLOCK key, the display shows on the bottom display the "dri" message, while the "hourglass" start flashing.
2.
Push again the CLOCK the duration of the dipping phase is shown, hh:mm.
3.
To set the duration push the UP and DOWN keys.
4.
Push again the CLOCK to confirm the time and pass to the setting of the running phase: the "on" message is displayed.
5.
Push the CLOCK key to see its duration and use the UP and DOWN keys to set it.
6.
Push again the CLOCK to confirm the time and pass to the setting of the stopping phase: the "oFF" message is displayed.
7.
Push the CLOCK key to see its duration and use the UP and DOWN keys to set it.
8.
Confirm the value by pushing again the CLOCK key and pass to the humidity display.
7.2 HOW TO SET THE TARGET HUMIDITY OF THE RUNNING CYCLE
1.
Push the SET %RH key, the display shows on the bottom display the "SH1" message, while the "set" icon starts flashing.
2.
Push again the SET %RH the humidity set point of the running phase is shown. Set it using the UP and DOWN keys. To disable the
humidity control during the freezing phase set it to "nu".
3.
Push again the SET %RH to confirm the value and pass to the humidity display.
7.3 HOW TO SET THE TARGET TEMPERATURE OF THE DRIPPING AND RUNNING PHASES
1.
Push the SET TEMP key, the display shows on the upper display the "StG" message, while the "set " icon starts flashing.
2.
Push again the SET TEMP the temperature set point of the running phase is shown. Set it using the UP and DOWN keys.
3.
Push again the SET TEMP to confirm the value and pass to the setting of the dripping phase: the "St1" message is displayed.
4.
Push the SET TEMP key to see its value and use the UP and DOWN keys to set it.
7.4 HOW TO START THE CYCLE
Push and release START
key: the led
The
led flashes during the proving phase
7.5 END OF THE CYCLE
When the timer has expired, the buzzer starts sounding and the bottom display shows the "End" message.
To mute the buzzer push a key: The display come back to show the humidity and the LED of the START key is turned off.
7.6 HOW TO STOP THE CYCLE MANUALLY
To stop the cycle manually push the ON/OFF key
7.7 HOW TO MODIFY THE SETTING OF THE CURRENT CYCLE WHILE IT'S RUNNING
To modify the setting of the running cycle temperature (SET TEMP), humidity (SET %RH) or remaining time (CLOCK):
1592017410 XLH360 GB r1.0 15.04.2005.doc
Operating Instructions
Stopping
Running
Stopping
will be turned ON.
.
XLH360
cod. 1592017410
5/16