Dixon Automatic Tool SKC-PTA-BE120 Handbuch für Betrieb und Wartung - Seite 15
Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Kraftschraubendreher Dixon Automatic Tool SKC-PTA-BE120 herunter. Dixon Automatic Tool SKC-PTA-BE120 17 Seiten. Automatic industrial cordless brushless power torque screwdrivers
1.
The best condition of using the tool is under 8 hours a day, do not over loaded.
2.
Do not attempt to repair or disassemble this cordless screwdriver without authorization. Always
have the device serviced by assigned factory or qualified person in order to have the warranty
effective continually.
3.
KILEWS is not responsible for any poor performance or damage caused by customers own
modification of the tool.
4.
It is necessary for the management to have individual operators read and follow up all
instructions in this manual. Do not attempt to repair or disassemble this cordless screwdriver
themselves.
5.
Chemicals, Acetone, Benzene, Alcohol, Thinner, Ketone, trichloroethylene, etc shall not be in
contact with the surface of the screwdriver in order to prevent chemical damage.
6.
Please follow instruction carefully and do not drop or shock the screwdriver.
7.
This is an external torque adjustment screwdriver, 0 on the torque adjust ring stands for
minimum torque and 8 for maximum torque. The rated operation time is 1 second / 3 seconds
(ON / OFF). Appropriate fastening frequency is 15 fasteners in each minute. Overrunning may
damage motor due to overheat. Proper amount of screwdriver resting is recommended to
prevent motor overheating.
Slow speed Duty Cycle Conversion (for reference)
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,
1000-350=650,650/1000%=65%
ON= 1*1.65= 1.65,OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF
This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off.
Slow speed
operation
(rpm)
frequency
900
1.0 ON 3.0 OFF
850
1.0 ON 3.0 OFF
800
1.0 ON 3.0 OFF
750
1.0 ON 3.0 OFF
700
1.0 ON 3.0 OFF
650
1.0 ON 3.0 OFF
8.
Not allow to turn the Hi/Lo switch during operation in order to cause system maltfunction.
9.
The device will not be able to function again once the OK/NG indicator/signal is not turn off
yet.
10. When adjusting the torque, for safety purpose should stop the screwdriver completely and set
the switch to neutral position. It could prevent the user from turning the tool on accidentally.
11. During operation, the switch has been changed accidentally that the device will enable its
self-protecting mode which is power off. Re-start the tool when this happen.
12. Each operational torque setting, using time and frequency may result in different level of wear
and tear, at higher torque setting and use extensively could accelerate the wearing down of tool.
After one month, the torque is getting reduction gradually at the rate of 2~3% or 3~5 %( max
torque). The longer use of the device, torque reduction will become stable and the users could
measure the torque by a tester on a regular time schedule to check if the torque power still
meets the criteria.
13. SKC-PTA-BE series cordless screwdriver are tested by our torque meter KTM-150.
14.
Kilews cordless screwdriver torque output is generated by clutch mechanism, and it is
applicable to ISO 6789.
Other Cautions
Slow speed
operation
(rpm)
frequency
600
1.0 ON 3.0 OFF
550
2.0 ON 5.0 OFF
500
2.0 ON 5.0 OFF
450
2.0 ON 5.0 OFF
400
2.0 ON 5.0 OFF
350
2.0 ON 5.0 OFF
14
Slow speed
operation
(rpm)
frequency
300
2.0 ON 5.0 OFF
250
2.0 ON 5.0 OFF
200
2.0 ON 5.0 OFF
150
2.0 ON 5.0 OFF
100
2.0 ON 5.0 OFF