PROGRAMMING INSTRUCTIONS:

To Set or Change the Time: To clear entire memory, press reset key. Hold
down the CLOCK key while pressing either the HOUR or MINUTE keys.
Continue pressing until the desired number is shown. Then simply lift finger
off the CLOCK key to set.
To Set program (On/Off Times): Press TIMER key once to enter into
program mode. Display will show "1 ON - - - -". Press the HOUR key and
then the MINUTE key to select the desired first ON time. Press TIMER key
once. Display will show "1 OFF - - - -". Repeat previous step to select the
desired first OFF time. Repeat the entire sequence to complete up to eight
ON/OFF times as desired. When programming is done, press the CLOCK key
then the SELECT key repeatedly until the indicator bar is above the word
"AUTO".
To Review Program: Press TIMER key repeatedly. When done, press the
CLOCK key to return to the time of day.
To Cancel/Change Part of the Program: Press TIMER key repeatedly until
the particular ON or OFF time appears. Set new ON or OFF time. (See: to set
programs)
To Override Automatic Operation: Press the SELECT key to move
indicator bar to the desired ON or OFF position. Note: Timer will not resume
automatic operation until indicator bar is repositioned above the word AUTO.
To Override Timer Status (On or OFF): Press "OVR", key. Timer will
resume automatic operation with the next opposite set point.