L). STARTING UP THE SYSTEM / SETTING THE BALL VALVE
Once everything has been connected, turn on the power to the Aqua Elite 50 unit. Make sure all the connec-
tions are complete and tight.
The next step is critical to the performance of the Aqua Elite 50.
The ball valve will need to the properly adjusted to maximize ozone output into the water. Adjust it with the
pool pump set to the lowest pump speed so that you will see a "frothing" effect in the clear view window of
the manifold assembly. This will appear to be very tiny milk-like bubbles. You will also be able to hear a
noise at the venturi injector and visually see some small bubble action coming out of the closest return line
(and possible other) in the pool.
Adjust the ball valve back until no bubbles and readjust until bubbles just appear and leave the ball valve set
at this "setting". This bubble/no bubble adjustment can be as sensitive as 1/16" to ¼" rotation after rough
audible or visual adjustment is made. It is recommended to mark this location with a marker in case the ball
valve is accidently changed.
NEVER LEAVE THE BALL VALVE CLOSED EXCEPT FOR THIS INITIAL ALIGNMENT
STAGE. VERY IMPORTANT.
Adjust valve to proper setting to obtain the "frothing" effect.
{
"Frothing"
Effect
(small bubbles)
The Healthy Alternative to Chlorine
10