EDI DA-300 Betriebshandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Prüfgeräte EDI DA-300 herunter. EDI DA-300 7 Seiten. Io tester
C.
Simulating a Detector Input
1.
There are 16 detector toggle switches labeled DET1 through DET16.
2.
When a detector toggle switch on the IO Tester is pushed up, the IO Tester
simulates that particular channel as a turned-on detector output or "call" to
the connected DA unit.
3.
When the detector toggle switch is pushed down, the IO Tester simulates
that particular channel as a turned-off detector output to the connected DA-
®
300
4.
All detector channels can be turned on or off at the same time or any
combination of on and off as required by the specific test or demonstration.
16 Detector Toggle Switches
Eberle Design Inc.
DA-300
Operations Manual
unit.
®
IO TESTER
Page 4