EDI 242E Betriebshandbuch - Seite 8

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Industrielle Elektrik EDI 242E herunter. EDI 242E 13 Seiten. Enhanced dc isolator unit

2.1 MECHANICAL

Height ............................................................................................................... 4.50 inches
Width ................................................................................................................. 1.2 inches
Depth (excluding handle) .............................................................................. 6.875 inches

2.2 ENVIRONMENTAL

Storage Temperature Range ...................................................................... -45 to +85
Operating Temperature Range ................................................................... -34 to +74
Humidity Range (non-condensing) ....................................................... 0 to 95% Relative

2.3 ELECTRICAL

AC Supply Voltage Minimum .................................................................................. 80 Vac
AC Supply Voltage Maximum ............................................................................... 135 Vac
AC Supply Power Maximum ...............................................................................2.5 Watts
DC Inputs
True (low)........................................................................................... less than 8 Vdc
False (high) ................................................................................. greater than 12 Vdc
Optically Isolated Solid State Outputs
True (low, 50 mA) ........................................................................... less than 1.5 Vdc
False (high) ................................................................................. greater than 16 Vdc
Maximum Leakage Current (high) ...................................................... less than 1 uA
Maximum Current .............................................................................................50 mA
Collector Voltage Maximum ............................................................................ 50 Vdc

2.4 TIMING

Input Pulse Width Reject (Filter A & B Off) ................................................ less than 5 ms
Input Pulse Width Accept (Filter A & B Off) ........................................ greater than 25 ms
Input Pulse Width Accept (Filter A & B Off) .................................................. typical 10 ms

2.5 CONNECTIONS

Edge Connector mates with connector type Cinch 50-44A-30
Eberle Design Inc.
Model 242E
Operations Manual
Section 2
Specifications
PIN
FUNCTION
D
Input CH 1
E
Input CH 1 Common
F
CH 1 Output Collector
H
CH 1 Output Emitter
J
Input CH 2
K
Input CH 2 Common
L
Equipment Ground
M
AC -
N
AC +
W
CH 2 Output Collector
X
CH 2 Output Emitter
o
C
o
C
Page 5