ARTHUR HOLM AHDTLM UC Benutzerhandbuch - Seite 11
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Mikrofon ARTHUR HOLM AHDTLM UC herunter. ARTHUR HOLM AHDTLM UC 16 Seiten. Motorized microphone system for underneath installation
Commands:
COMMAND
DESCRIPTION
FA XX 01 01 00
GO UP
FA XX 01 00 00
GO DOWN
FA XX 02 01 00
MUTE ON (Only in PA mode)
FA XX 02 00 00
MUTE OFF (Only in PA mode)
FA XX 04 01 00
BUTTON LOCK
FA XX 04 00 00
BUTTON UN LOCK
FA XX 14 00 00
INQUIRY CONTROL BYTE
XX: Number of the DynamicTalk address. Up to 30 units for each RS422
BUS.
CB1: Response in 8 bites of the device status
CB2: Not implemented
CB1:
BIT 0
TOP POSITION
BIT 1
DOWN POSITION
BIT 2
(1) MUTE ON
BIT 3
(1) BUTTON LOCK
BIT 4
BIT 5
BIT 6
BIT 7
(1) FAILURE IN THE SYSTEM
To send an order to all the devices, you must use the address:
F7 Hex. (Byte1)
In this case, the units do not respond
RESPONSE
FB XX 01 01 00
FB XX 01 00 00
FB XX 02 01 00
FB XX 02 00 00
FB XX 04 01 00
FB XX 04 00 00
FB XX 14 CB1 CB2
11