The sensor cannot connect to the cloud (status LED flashes):
1. Check whether the ports TCP 443, 3032, 8883 and
UDP 123 of the wireless router are open.
2. Perform a hard reboot by pressing the RESET
button for more than 5 seconds (and less than 10
seconds) and wait 3 minutes.
3. Some charging station models have their own DNS
server which may interfere with the setup process.
Plug charging stations into the router last so that
the IP address is given by the router and not by the
charging station.
I have installed the CLEMAP product correctly and registered it on the platform,
but the data is not accessible on floem.clemap.com:
Check whether the sensor is communicating with
sensor. If this flashes or is switched off, check whether the radio connection is also accessible when the control
cabinet door is closed (install a repeater if necessary) and whether the router doors are open.
→ See question: The sensor cannot connect to the cloud (status LED flashes).
If the status LED is constantly lit, check at
not the case, please contact support.
Do you have any further questions about the installation? We will be happy to
answer them at
Figure 16 Hard Reboot
https://floem.clemap.com
https://floem.clemap.com
by looking at the LED status on the
whether the measuring point is online. If this is
or by phone +41 44 548 20 61.