In the "Wireless Remote Control Function" setting, after the setting page is turned off, the
remote control function will be invalid, but the previously matched remote control data is
still saved. After this function is turned on, the remote control function will work normally.
5.1.7
K-2 wired controller (standard)
An S5 socket interface is reserved on the machine, which can be connected to the K-2
controller for remote control. Timing control, and manual control of snow output work.
5.2
DMX Operation
After the machine is connected to the DMX signal, the LCD screen can only display the
DMX512 address setting page. At this time, it can be used to modify the DMX512 address
code at any time.
H-S6 has two channels
Channel
Function
1
Wind output level
2
Snow output level
6
TECHNICAL INFORMATION
6.1.1
Maintenance
H-S6 needs regular cleaning and maintenance to achieve the best results. Some cleaning and
maintenance steps are essential. Here are the recommended cleaning steps:
•
Unplug the product from power.
•
Empty snow fluid from the machine.
•
Add water to the snow fluid tank.
•
Connect the product to power and allow it to warm up. Run the Cleaning Mode.
Thoroughly rinse the snow fluid reservoir and fluid tube.
•
Run the product in a well-ventilated area. Do not allow the pump to run dry.
•
Add snow fluid again to continue using WP-4. Run the machine briefly to remove any
remaining clean water from the oil pump and heater.
Value
Status
0-5
Off
6-250
Fan Output 1-100%
251-255
Strong wind mode
0-5
Off
6-250
Snow Output 1-100%