Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local
codes and authorities having jurisdiction .
Wiring should be UL Listed and/or Recognized wire suitable for the application .
eBridge100SPR and eBridge4SPT is not intended to be connected to outside plant leads and should be installed
indoors within the protected premises . eBridge100SPR and eBridge4SPT are intended for indoor use only .
1 . eBridge100SPR installation:
a . Secure unit to desired mounting surface with a proper fastening device utilizing the unit's mounting hole .
Unit should be mounted in proximity to Ethernet switch/network, NVR or video server .
b . Connect 56VDC UL Listed Class 2 or limited power source to terminals marked [Power – Input +]
(observe proper polarity) (Fig. 1, pg. 5) . Use 22AWG-16AWG wire for this connection .
Caution: 56VDC will be present on coax . The other end of the coax should only be connected to the
eBridge4SPT .
c . Connect structured cable from Ethernet switch/NVR (network video server) to RJ45 jack marked
[10/100 BaseT] (Fig. 1, pg. 5) .
d . Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 5) .
2 . eBridge4SPT installation:
a . Affix rubber pads to eBridge4SPT for shelf installation (Fig. 3, pg. 8) .
b . Connect Coax cable from eBridge100SPR to BNC connector marked [Coax] located on the back of the
unit (Fig. 1, pg. 5).
c . Connect structured cable from PoE/PoE+ cameras/devices to RJ45 jacks marked [1-4] (Fig. 1, pg. 5) .
Note: The eBridge is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras . It is
important to note that some high resolution and high frame rate cameras may demand faster headend processing
ability, such as a PC graphics card to present a quality image . If the headend processing equipment is insufficient
in speed, the image may show pixelation and latency . It is advisable to pre-test system if unsure . Alternatively,
frame rate and resolution may be reduced to accommodate system equipment .
Parameter
Connections
Input Power
Requirements
Indicators
Environmental
Conditions
Regulatory
Compliance
Weights (approx.)
- 4 -
Installation Instructions:
Technical Specifications:
Description
BNC for Coax link . RJ45 for Ethernet link .
eBridge100SPR - 51-56VDC/60W @ max . power .
eBridge4SPT - powered by eBridge100SPR .
Blue:
Yellow (RJ45 connector):
Green (RJ45 connector):
Operating Ambient Temperature (UL60950-1):
eBridge100SPR:
eBridge4SPT (60W):
Relative humidity:
Storage Temperature:
Operating Altitude:
UL/cUL Listed for Information Technology Equipment (UL 60950-1) . CE approved .
eBridge100SPR:
eBridge4SPT:
Coax Link .
On - Link, Off - No Link, Blinking - Activity .
On - 100Base-TX, Off - 10Base-T .
– 40ºC to 60ºC (– 40ºF to 140ºF) .
– 40ºC to 75ºC (– 40ºF to 167ºF) .
85%, +/ – 5%
– 40ºC to 75ºC (– 40ºF to 167ºF) .
– 304 .8 to 2,000m .
Product: 5 .1 oz . (0 .144 kg)
Product: 2 .9 lbs . (1 .32 kg)
| Shipping: 7 .76 oz . (0 .22 kg) .
| Shipping: 3 .9 lbs . (1 .77 kg) .