Part V:Troubleshooting
Adjust carriage hold downs (slide guides).
Check for wood chips or debris between ram bushing plate and
beam.
Check rack lift bearing for alignment or damage.
Return spring is unhooked or damaged. Reconnect or replace as
needed.
Machine wedge end too low. Must be almost level or wedge end
slightly higher.
Lever not all the way forward when rack comes under full load.
Push lever quicker and more forcefully into the full forward
position.
Ram has been overloaded at lower part of face. Check rack gear
for straightness.
Wedge end of machine too high. Must be almost level with ram
end or just slightly higher.
Springs not operating properly. Fix or replace as needed.
The belts may be too loose and slipping. Adjust or replace belts as
needed.
Clean wood chips or other debris from under rack.
Clean accumulated dirt from frame where carriage assembly rests
against rubber bumpers.